background image

AT-5771 Air Crimp Tool Head 

Doc. No: ATS-640054500 

Release Date: 11-07-03 

UNCONTROLLED COPY

 

Page 2 of 6 

Revision: C 

Revision Date: 03-19-12 

Figure 2 

LOCATOR 

TERMINAL 

CONDUCTOR 

PUNCH 

CONDUCTOR 

ANVIL 

WIRE 

 

OPERATION 

 
Refer to the instruction manual for the 19279-0001 (AT-200) for 
mounting this crimp tool head. 
 

Crimping Terminals

 

1.

 

Adjust the locator up or down until the terminal being run sits flat 
and straight in the tool. 

2.

 

Position the locator for the proper color-coded nest by removing the 
#4-40 by 3/8” long BHCS under the bracket of the locator.  Place it 
in the desired position that corresponds with the color-coded nest 
being used.  Tighten the BHCS. 

3.

 

Insert the wire into the terminal.  Push the terminal and wire against 
the locator in the proper color-coded nest.  The barrel of the 
terminal should be up.  See Figure 1. 

 

Caution: 

Never operate this tool without the supplied safety shield in place.  Never place fingers in the tool nests. 

 
4.

 

Push on the wire to assure it is still fully seated in the 
terminal. The wire end should butt against the wire stop 
stamped into each terminal.  See Figure 2.  Cycle the tool.

 

5.

 

Remove the crimp and inspect for proper crimp location, 
and check for insulation closure.  Molex offers a Crimp 
Inspection Handbook for closed barrel industrial product.  
See our website or contact your sales engineer. 

 

Maintenance 

 
It is recommended that each operator of the tool be made 
aware of, and responsible for, the following maintenance steps: 
 
1.

 

Remove dust, moisture and other contaminants with a clean brush, or soft, lint-free cloth. 

2.

 

Do not use any abrasive materials that could damage the tool. 

3.

 

Make certain all pins; pivot points and bearing surfaces are 
protected with a thin coat of high quality machine oil.  Do not oil 
excessively.  This tool was engineered for durability, but like any 
fine piece of equipment it needs cleaning and lubrication for a 
maximum service life of trouble-free crimping.  Use a light oil, 
such as 30 weight automotive oil at the oil points shown in Figure 
3, every 5,000 crimps or monthly will significantly enhance the 
tool life and ensure a stable calibration. 

4.

 

When tool is not in use store the tool in a clean, dry area.  

 
 
 

SAFETY 

SHIELD 

WIRE 

BARREL OF 

TERMINAL 

Figure 1 

LOCATOR 

JAWS OPEN 

TERMINAL 

LUBRICATION POINTS 

(BOTH SIDES) 

LIGHT OIL (EVERY MONTH 

OR 5,000 CRIMPS) 

Figure 3 

Summary of Contents for Perma-Seal 64005-4500

Page 1: ...perties of the crimped connections The following charts show the UL specifications for various wire sizes The tensile strength is shown in pounds and indicates the minimum acceptable force to break or separate the terminal from the conductor Wire Size AWG UL 486 A UL 486 C UL 310 Min Pull Min Pull Min Pull 22 8 8 8 20 13 10 13 18 20 10 20 16 30 15 30 14 50 25 50 UL 486 A Terminals copper conductor...

Page 2: ...ed into each terminal See Figure 2 Cycle the tool 5 Remove the crimp and inspect for proper crimp location and check for insulation closure Molex offers a Crimp Inspection Handbook for closed barrel industrial product See our website or contact your sales engineer Maintenance It is recommended that each operator of the tool be made aware of and responsible for the following maintenance steps 1 Rem...

Page 3: ...ire Range X Dimension Conductor Crimp Crimp Inspection Marking AWG mm Mean Go No Go Red 18 22 0 35 0 80 094 090 098 Blue 14 16 1 30 2 00 115 110 119 Yellow not used NA NA NA NA NA Warranty This tool is for electrical terminal crimping purposes only This tool is made of the best quality materials All vital components are long life tested All tools are warranted to be free of manufacturing defects f...

Page 4: ...N INSERT M4 FLAT WASHER 4 5 4 40 X 3 8 LG SHCS PARTS LIST Item Order No Description Quantity 64005 4500 Crimp Tool Head Figure 4 1 64005 0000 Basic Air Tool Head 1 2 64001 4575 Locator Assembly 1 3 64001 4570 Tooling Kit 1 Tooling Kit Only 4 64001 4502 Conductor Punch 1 5 64001 4501 Conductor Anvil 1 Available from an Industrial supply company such as MSC 1 800 645 7270 ...

Page 5: ...s List Continued Item Order No Description Quantity 64005 0000 Basic Air Tool Head Figure 5 1 64005 0103 Nose Guard 1 2 64000 0077 Repair Kit Springs Rods Pivots Rings and Washers 1 3 N A M4 by 12 Long Freedrive Pan Head Screw 1 4 N A M4 by 25 Long Freedrive Pan Head Screw 1 5 N A 3 16 by 3 8 Long Dowel Pin 1 Available from an Industrial supply company such as MSC 1 800 645 7270 ...

Page 6: ..._____________ Serial Number_____________________ Date of Manufacture Pin Gauge of Conductor Nest Nests or Slug height if the nest is the F Crimp style Range Conductor Nest 1 ____________ Actual ____________ Range Conductor Nest 2 ____________ Actual ____________ Range Conductor Nest 3 ____________ Actual ____________ Technician _______________________ Date of Calibration __________________ Calibra...