background image

 

 

 

 

 

EC/ECM NO: 

108434

 

SAP  NO : 

187000366

 

Doc No: 

AS-18700-101 

Doc part:

 AS

 

REV- 

A1

 

SAP EC  NO:  

10794823

 

http://www.molexpn.com/ 

 

DATE: 

2016/SEP/27

 

MPN/FMT-042 (2016/07/01 REV-00).                                                                                                                                                                                                                                                                            
THIS INFORMATION IS CORRECT AS AT THE TIME OF PUBLICATION, SPECIFICATION ARE SUBJECT TO CHANGE                                                                                                                SHEET No. 

1

 of 

4

 

INSTALLATION INSTRUCTIONS

 

BEFORE INSTALLING OR ADJUSTING THIS PRODUCT,                                                                                                         
PLEASE READ THESE INSTRUCTIONS CAREFULLY. 
PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE

 

RFR-00082 

– 1U 24 PORT CONFIGURABLE FIBER SLIDING DRAWER 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
DIRECTION BELOW APPLY SPECIFICALLY TO THE ENCLOSURE 

 
Installing adjustable mounting angles (Fig.1) 

  The mounting brackets can be installed in one of two positions which effects Depth of the 

enclosure is installed in the rack or cabinet. 

  Use M4 Philips pan head screws to attach mounting brackets to the enclosure. 

 

 

 

Fig.1 

 

 Open/close slide drawer (Fig.2) 

  Release the plunger from grommet. 

  Use even pressure on both the right and left side to pull and push the drawer. 

  Slide drawer out to its point of full extension. 

 

 

 

Summary of Contents for RFR-00082

Page 1: ...EP THIS GUIDE FOR FUTURE REFERENCE RFR 00082 1U 24 PORT CONFIGURABLE FIBER SLIDING DRAWER DIRECTION BELOW APPLY SPECIFICALLY TO THE ENCLOSURE Installing adjustable mounting angles Fig 1 The mounting brackets can be installed in one of two positions which effects Depth of the enclosure is installed in the rack or cabinet Use M4 Philips pan head screws to attach mounting brackets to the enclosure Fi...

Page 2: ...ls Fig 3 Spools are secured using kep nuts Note Do not install slack management Spools for Mod link MTP cable and Modular Splice Cassette installations Fig 3 Back Cable Entry Retention Fig 4 Cables can enter in either the left or right back side of the enclosure Secure cables with Velcro strips or cable ties to the strain relief tie off feature Fig 4 OPEN CLOSE ...

Page 3: ...6 of slack b w the cable entry point and the point where the cable begins to spool around the slack management spools or Velcro straps Do not install slack management spools when using Mod link MTP assemblies Mark cable jacket 18 back from MTP connector with a marker Secure cable with Velcro or wire ties at the point of entry Route the slack inside the enclosure around the spool Group cables by si...

Page 4: ...hey will go no further o Installing Mod Link Cassettes Up to four Mod link cassettes may be installed in the enclosure Mod link cassettes utilize corner retention push pins which when pulled upon open two corner fasteners Position the Mod link cassettes in the appropriate location within the enclosure and push the two corner fasteners gently back until they will go no further Splice Cassette insta...

Reviews: