Molnar Hoists
All Rounder
Servicing
6
Wire Rope and Failure Test
Wire Rope Failure Test
Wire Rope Test (Automatic Safety Test)
1
Raise Hoist to approximately 600mm and ensure LOCK
lever is in OFF position.
2
Using a lifting device (such as a Wallaby Jack), raise the
non-control-post carriage another 200mm. Ensure the
toggles on the back of the non-control-post carriage
engage onto safety teeth.
If safety toggles do not engage, toggles may need to
be lubricated or springs may need to be replaced
3
Check the manual safety has automatically reset to the
ON position on the control post carriage.
4
Remove Jack
5
Raise the hoist and reset the safety to the OFF position
and ‘jack’ the control carriage to test the manual safety
resets automatically to the ON position and remove jack.