3) Connect the test tips with the measuring
points of the circuit to be tested. The multi-
meter automatically selects the suitable
measuring range within the selected cur-
rent range. The measured value is dis-
played as a digital number as well as an
analog bargraph. Overflow, i. e. current
measurement values beyond the dis-
played current ranges are signalized by
the display OL.
5.3
Resistance measurement
ATTENTION! With resistance measurements
the circuit to be tested must be separated
from the power supply.
1) Set the rotary switch (5) to the position
„
Ω
•
•
“. Open test leads are signal-
ized by the display OL.
2) Connect the test tips with the measuring
points of the circuit to be tested. The multi-
meter automatically selects the suitable
measuring range. The display (1) shows
the selected measuring range and the
measured value. The measured value is
displayed as a digital number as well as an
analog bargraph.
5.3.1 Resistance measurement with
continuity buzzer
1) With the rotary switch (5) set to position
„
Ω
•
•
“ press the selector but-
ton (3). The multimeter is in the continuity
GB
18