8
Specifications
DC voltage
Measuring ranges: . 25 mV, 250 mV, 2.5 V,
25 V, 250 V, 600 V
Measuring accuracy*
25 mV: . . . . . . . . ±(1.0 % + 10 digits)
250 mV: . . . . . . . ±(0.25 % + 5 digits)
2.5 V – 600 V: . . ±(0.25 % + 1 digit)
Input resistance
25 mV: . . . . . . . . > 1 G
Ω
250 mV – 600 V: . > 10 M
Ω
Overload protection
25 mV: . . . . . . . . safety fuse
0.5 A/250 V, quick-acting
250 mV – 600 V: . 600 V
/~
AC voltage
Measuring ranges: . 25 mV, 250 mV, 2.5 V,
25 V, 250 V, 600 V
Frequency range: . 50 – 500 Hz
Measuring accuracy*
25 mV: . . . . . . . . ±(1.0 % + 10 digits)
250 mV: . . . . . . . —
2.5 V – 600 V: . . ±(0.75 % + 4 digits)
Input resistance: . . 10 M
Ω
Overload protection: 600 V
/~
DC current
Measuring ranges: . 250 µ A, 2.5 mA, 25 mA,
250 mA, 2.5 A, 10 A
Measuring accuracy*
250 µ A, 25 mA: . ±(0.75 % + 10 digits)
2.5 mA, 250 mA:
±(0.75 % + 1 digit)
2.5 A, 10 A: . . . . ±(0.75 % + 4 digits)
Overload protection by safety fuse
250 µ A – 250 mA: 0.5 A/250 V, quick-acting
2.5 A, 10 A: . . . . 10 A/600 V, quick-acting
AC current
Measuring ranges: . 250 µ A, 2.5 mA, 25 mA,
250 mA, 2.5 A, 10 A
Frequency range: . 50 – 500 Hz
Measuring accuracy*
250 µ A – 250 mA: ±(1.5 % + 2 digits)
2.5 A, 10 A: . . . . ±(3.0 % + 2 digits)
Overload protection by safety fuse
250 µ A – 250 mA: 0.5 A/250 V, quick-acting
2.5 A, 10 A: . . . . 10 A/600 V, quick-acting
Resistance
Measuring ranges: . 250
Ω
, 2.5 k
Ω
, 25 k
Ω
,
250 k
Ω
, 2.5 M
Ω
, 25 M
Ω
Measuring accuracy*
250
Ω
: . . . . . . . ±(0.3 % + 3 digits)
2.5 k
Ω
– 2.5 M
Ω
: ±(0.3 % + 1 digit)
25 M
Ω
: . . . . . . . ±(3.5 % + 4 digits)
max. measuring
voltage: . . . . . . . . . 0.4 V
Overload protection: 500 V
/~
Continuity buzzer
Response threshold: < 30
Ω
Overload protection: 500 V
/~
Capacitance
Measuring ranges: . 2.5 nF, 25 nF, 250 nF,
2.5 µ F, 25 µ F
Measuring accuracy*
2.5 nF: . . . . . . . . ±(10 % + 10 digits)
25 nF – 25 µ F: . . ±(3.0 % + 10 digits)
Overload protection: 500 V
/~
Frequency
Measuring ranges: . 5 Hz, 50 Hz, 500 Hz,
5 kHz, 50 kHz, 500 kHz,
5 MHz
Measuring accuracy*: ±(0.05 % + 2 digits)
Measuring sensitivity
5 Hz – 500 kHz: . 1 V
5 MHz: . . . . . . . 5 V
Overload protection: 500 V
/~
Pulse duty factor
Measuring range: . 0.1 % to 99.9 %
Frequency range: . 2 Hz to 20 kHz
Overload protection: 500 V
/~
Forward voltage of diode
Measuring range: . 1 V
Measuring accuracy*: ±(3.0 % + 3 digits)
Measuring current:
0.5 mA, ±0.3 mA
General information
Display: . . . . . . . . . 16 mm LCD, 3
1
/
2
digits
Measuring rate: . . . 2.5 measurements/sec.
Power supply . . . . .: 1 x 9 V battery
Battery life: . . . . . . approx. 200 h
(zinc-carbon battery)
Range of application: 0 – 40 °C,
rel. humidity < 70 %
Dimensions: . . . . . . 95 x 195 x 56 mm
Weight: . . . . . . . . . 430 g
*at 23 °C, ±5 °C
According to the manufacturer.
Subject to change.
GB
21