48
English
6.3.2 View MAIN
(fig . 8)
[1] Buttons to switch over the view (change of view only possible at
the access level “Administrator”)
[2] UNIT CONNECTION – connection status
green = connected
red = not connected
[3] Name of unit; unit can be renamed
[4] PC PRESET
“SAVE” the current settings as presets on the computer (like
menu item “File
Save”) and “LOAD” the presets from the com-
puter (like menu item “File
Open”)
[5] SPEAKER PRESET
“SAVE” the current settings as presets in the speaker and “LOAD”
the presets from the speaker
Select the storage location in the list field and enter a name in
the upper field .
Note:
To allow selection of a preset from the group control, save the preset
to one of the storage locations 10 – 19 .
[6] INPUT CONTROL for setting the gain (volume) for the inputs, level
indicators next to the control, input /display fields as a numeric
input facility beneath the control
[7] Level indicator MASTER LEVEL for the outputs LF (bass speaker)
and HF (tweeter)
[8] LINK switch (for controlling the two input channels together)
Channel IN-B will adopt the settings of channel IN-A .
[9] MUTE switch for muting the corresponding input
[10] List field to select the unit of measurement for the DELAY value
[11]: time or distance (for automatic calculation of the delay)
[11] Input /display field DELAY for setting the signal delay of the input
signals (e . g . to compensate differences in sound delay due to
different distances of individual speakers to the listening position)
Alternatively, use the sliding control to set the signal delay .
[12] List field to select the filter type for the high pass filter LOW CUT
with the following options:
Indication
Filter type
Slope
But 6dB
Butterworth
6 dB/octave
Bes 6dB
Bessel
6 dB/octave
But 12dB
Butterworth
12 dB/octave
Bes 12dB
Bessel
12 dB/octave
L-R 12dB
Linkwitz-Riley
12 dB/octave
But 18dB
Butterworth
18 dB/octave
Bes 18dB
Bessel
18 dB/octave
But 24dB
Butterworth
24 dB/octave
Bes 24dB
Bessel
24 dB/octave
L-R 24dB
Linkwitz-Riley
24 dB/octave
[13] High pass filter LOW CUT: Input /display field for the cut-off
frequency (enter values in Hz, “Off” < 20 Hz)
Alternatively, use the sliding control to set the frequency .
Summary of Contents for IT-400DT
Page 2: ...2 ...
Page 21: ...21 Deutsch Abb 8 Konfigurationsfenster in der Ansicht MAIN 1 2 6 7 8 13 9 11 3 4 5 12 10 ...
Page 23: ...23 Deutsch Abb 9 Ansicht IN A 14 15 16 18 19 20 21 22 17 23 24 25 ...
Page 49: ...49 English Fig 8 Configuration window in the view MAIN 1 2 6 7 8 13 9 11 3 4 5 12 10 ...
Page 51: ...51 English Fig 9 View IN A 14 15 16 18 19 20 21 22 17 23 24 25 ...