/ MONARCH DUPLEX SERIES DUAL POWER WATER SOFTENER 

PROGRAMMING & INSTALLATION INSTRUCTIONS 

Thank you for choosing our water softener. Please read the following carefully, which if followed 

correctly, should ensure the installation is trouble free. 

/ A. PLANNING THE INSTALLATION

• Always observe the water byelaws.

• Ensure there is only one rising main.

• Make sure you have allowed space for access to the unit for salt filling and for any possible

maintenance in the future.

• Check the water pressure and locate the rising main, and a drain facility. Be aware of condensation

on pipes and the outside of the softener occurring in warm environments.

• This softener has reversible valve technology, meaning the valve connector can be located on either

side of the softener allowing easier installation and siting. If you would like to relocate the valve

connection, please see the Reversible Connections section starting on page 10 of these instructions.

/ B. SITING THE SOFTENER - Fig 1

• Where possible, this should be close to the rising main.

• Tee off for mains water supply to outside tap if applicable.

• Rapid-Fit bypass has a 3/8” speedfit connection for flexi tube connection to a dedicated drinking

water faucet. Please enquire today to find out more about our Monarch drinking water Tap on

+44 (0) 1986 784759 (opt 1) or email info@monarchwater.co.uk

• The distance between the softener and the drain should be as short as possible, to ensure that both

the drain and the overflow are not subject to freezing, or over 120° F/49°C.

• If siting the softener within a kitchen cupboard, loft etc. ensure that the base/ floor is adequately

supported.

• If the softener is being installed in your loft, 1st, 2nd floor etc, it is strongly recommended to house

the softener within a 25-gallon plastic tank and insulate well. Monarch take no responsibility of any

water damage etc if this recommendation is not applied.

• The overflow on the plastic tank should be below the overflow of the softener and a minimum of

¾”in size. Failure to install the softener in a suitable tank will void the warranty.

3

/ C. CHECK VALVE 

Domestic Ion exchange water softeners are in fluid category 2. The Rapid-Fit bypass incorporates a 

high flow check valve in accordance with this requirement. All other applications require a double 

check valve. 

/ D. DRINKING WATER FACILITY 

See Installation Requirements Diagram In compliance with U.K. Water Regulations a tap for 

drinking water purposes should be left on the hard water supply. See Rapid-Fit bypass 3/8” speedfit 

connection. 

/ E. MATERIAL CHECK LIST 

Ensure all installation components comply with appropriate water regulations.

• PSU027HE & PSP022HE includes a Monarch Rapid-Fit bypass installation kit suitable for 15mm

and 22mm plumbing systems.

• For 15mm pipework use the compression reducers supplied.

• For 28mm supplies a full upgrade of the softener is available - details on request - ref PS28UGHE.

Summary of Contents for ULTIMATE PREMIO HE

Page 1: ......

Page 2: ...led in a manner that protects human health and the environment 2 ULTRA HE PREMIO HE Model Dims H x W x D mm Family size Daily capacity litres 300 ppm Salt use per regen kg Max flow rate lpm Water Pressure bar Max Op Temp C Connection Ultra HE 557 x 269 x 489 1 10 1 520 Tablet Block 0 84 1 2 65 1 5 5 49 3 4 mbsp Premio HE 788 x 269 x 489 2 20 3 040 Tablet 1 68 2 4 61 1 5 5 49 3 4 mbsp If using Ultr...

Page 3: ...stance between the softener and the drain should be as short as possible to ensure that both the drain and the overflow are not subject to freezing or over 120 F 49 C If siting the softener within a kitchen cupboard loft etc ensure that the base floor is adequately supported If the softener is being installed in your loft 1st 2nd floor etc it is strongly recommended to house the softener within a ...

Page 4: ...3 4 FI 28 x 1 FI to Rapid Fit bypass 1 Fibre washers are pre inserted against shoulder inside brass female thread Fig A IMPORTANT Do not use 3 4 industry standard washers here 2 For additional security Fernox LS X or Loctite SI 5331 may be used Simply apply to male thread of noryl bypass adaptor and to inside of female thread of brass fitting Fig B In all cases fibre washer must be used 3 Tighten ...

Page 5: ... can reach nearly 100psi at night Minimum dynamic pressure must exceed 1 5 bar If in any doubt please call us on 44 0 1986 784759 G INSTALL RAPID FIT BYPASS If using the Rapid Fit Bypass form an installation as per Fig 1 below See previous page for more information Fig 1 Check List Access to drain Installation preferably on an outside wall for the overflow Easy access to fill unit with salt Water ...

Page 6: ... on the side pictured green in Fig 2 Fix drain hose to white barbed elbow with jubilee clip supplied Run the drain hose to either an upstand or an outside drain A minimum air gap of 20mm should exist at the end of the drain line If you need to extend the drain hose this can be done by connecting to a 15mm copper tube for a maximum run of 4 metres with a minimum daytime pressure of 40 psi Over 4 me...

Page 7: ...y If the water sample contains hardness it will turn red Add the dark solution in batches of 5 drops holding the dropper bottle at 45 degrees Mix gently after each 5 drops Count the drops needed until the colour of the sample in the test tube changes from a dark red to a dark blue green You need this figure for when SET WATER HARDNESS as per O overleaf M SETTING THE ELECTRONIC CONTROLLER Ensure ba...

Page 8: ...on initial installation Place Rapid Fit bypass in Service position by pushing plunger as per directional arrow see Fig 4 previous page Check for leaks Leave a soft mains tap e g bathroom wash hand basin to run for a minimum of 5 minutes to purge any air and resin dust from the softener resin dust may appear orange in colour Please ensure the unit is kept full of salt The Ultra HE can use either ta...

Page 9: ...anual regeneration by pressing left hand button on controller Display will countdown from 15 to zero Please be aware that during the regeneration the softener goes onto automatic hard water bypass so it is recommended to use washing machine etc after the regeneration is finished when full soft water will resume 9 FURTHER INFORMATION Please do not remove the mesh bag that surrounds the brine draw T...

Page 10: ... REVERSIBLE CONNECTIONS Remove salt lid and side access panel 10 ...

Page 11: ...Remove top cover 1 2 11 ...

Page 12: ...Remove any internal packaging 12 ...

Page 13: ...Loosen the jubilee clip and disconnect the drain tubing from the elbow inside the cabinet Then remove the complete unit Jubilee clip 13 ...

Page 14: ...Remove the blue clip Push fit connection Release tubing 14 ...

Page 15: ... unit supports at the top of the vessels 180 degrees Retighten the large nut to secure the valve in place Undo the large nut at the base of the main valve body take out the valve and twist 180 degrees until the connections are on the other side 15 ...

Page 16: ...grey clip from the air check connector Remove the connector and ro tate 180 degrees Using the supplied fittings and tubing 8cm attach the air check to the valve using the push fit connector and placing the blue clip back on as pictured Air check connec tor 16 ...

Page 17: ...using the jubilee clip this can only be done once it is in the cabinet Ensure the drain hose is not kinked Finally put the top cover salt lid and side panel back into place Remove the drain elbow from the side of the cabinet and place it on the opposite side 17 ...

Page 18: ...d in certain cases this will also apply to rinse aid On dishwashers connected to hard water you should continue to put salt into the dishwasher s own softener If in any doubt if your machine should have either hard or soft water please contact your dishwasher manufacturer but remember they want to sell you spare parts to replace those that get scaled up 7 Steam Irons We do not recommend the use of...

Page 19: ... Service See Fig 4 P 9 4 Callouts due to incorrect installation If you have any queries when installing your softener please call your supplier 5 The wrong type of salt used and the softener being allowed to run out of salt NOTE Use TABLET OR BLOCK SALT for the Ultra HE and TABLET SALT ONLY for the PREMIO HE 6 The use of any other hoses than those provided Under no circumstances use washing machin...

Page 20: ...ranty has expired Monarch reserves the right to make a charge for any postage delivery labour and parts charges that is deemed necessary Monarch will endeavour to keep these charges at the lowest cost whenever possible SERVICE CARE The manufacturer of your water softener includes 55 years of manufacturing experience to give you a water softener that is arguably the most reliable on the market toda...