/ MONARCH DUPLEX SERIES DUAL POWER WATER SOFTENER
PROGRAMMING & INSTALLATION INSTRUCTIONS
Thank you for choosing our water softener. Please read the following carefully, which if followed
correctly, should ensure the installation is trouble free.
/ A. PLANNING THE INSTALLATION
• Always observe the water byelaws.
• Ensure there is only one rising main.
• Make sure you have allowed space for access to the unit for salt filling and for any possible
maintenance in the future.
• Check the water pressure and locate the rising main, and a drain facility. Be aware of condensation
on pipes and the outside of the softener occurring in warm environments.
• This softener has reversible valve technology, meaning the valve connector can be located on either
side of the softener allowing easier installation and siting. If you would like to relocate the valve
connection, please see the Reversible Connections section starting on page 10 of these instructions.
/ B. SITING THE SOFTENER - Fig 1
• Where possible, this should be close to the rising main.
• Tee off for mains water supply to outside tap if applicable.
• Rapid-Fit bypass has a 3/8” speedfit connection for flexi tube connection to a dedicated drinking
water faucet. Please enquire today to find out more about our Monarch drinking water Tap on
+44 (0) 1986 784759 (opt 1) or email info@monarchwater.co.uk
• The distance between the softener and the drain should be as short as possible, to ensure that both
the drain and the overflow are not subject to freezing, or over 120° F/49°C.
• If siting the softener within a kitchen cupboard, loft etc. ensure that the base/ floor is adequately
supported.
• If the softener is being installed in your loft, 1st, 2nd floor etc, it is strongly recommended to house
the softener within a 25-gallon plastic tank and insulate well. Monarch take no responsibility of any
water damage etc if this recommendation is not applied.
• The overflow on the plastic tank should be below the overflow of the softener and a minimum of
¾”in size. Failure to install the softener in a suitable tank will void the warranty.
3
/ C. CHECK VALVE
Domestic Ion exchange water softeners are in fluid category 2. The Rapid-Fit bypass incorporates a
high flow check valve in accordance with this requirement. All other applications require a double
check valve.
/ D. DRINKING WATER FACILITY
See Installation Requirements Diagram In compliance with U.K. Water Regulations a tap for
drinking water purposes should be left on the hard water supply. See Rapid-Fit bypass 3/8” speedfit
connection.
/ E. MATERIAL CHECK LIST
Ensure all installation components comply with appropriate water regulations.
• PSU027HE & PSP022HE includes a Monarch Rapid-Fit bypass installation kit suitable for 15mm
and 22mm plumbing systems.
• For 15mm pipework use the compression reducers supplied.
• For 28mm supplies a full upgrade of the softener is available - details on request - ref PS28UGHE.
Summary of Contents for ULTIMATE PREMIO HE
Page 1: ......
Page 10: ... REVERSIBLE CONNECTIONS Remove salt lid and side access panel 10 ...
Page 11: ...Remove top cover 1 2 11 ...
Page 12: ...Remove any internal packaging 12 ...
Page 14: ...Remove the blue clip Push fit connection Release tubing 14 ...
Page 21: ... 44 0 1986 784759 monarchwater co uk info monarchwater co uk ...