Monark 891 E/891 E Wingate Option
12
Troubleshooting guide 891 E
Symptoms
Probable Cause/Corrective Action
The weight basket moves up and
down.
The brake belt contact surface may need to be ground off. See
•
description in section “Brake belt contact surface”.
The weight basket touch the flywheel.
The brake cord is probably not enough tightened.
•
The basket can be loaded with a lot of weight. Tighten the brake cord.
•
See the section "Adjustment brake cord tension".
According to test the bike seems to give
too high workload.
The brake cord may be too tighten. Loosen the cord according to
•
section “Adjustment brake cord tension”.
There is a click noise with every pedal
revolution (increases with the weight).
The pedals are not tight. Tighten them or change pedals.
•
The crank is loose. Check, tighten.
•
The base bearing is loose. Contact your dealer for service.
•
Scratching sound is heard when pedalling.
Check that the carriage block is taken off and that none of the covers is
•
scratching.
There is a click noise and a squeak noise
when pedalling.
Loosen the chain.
•
No heart rate displayed.
Check the chestbelt (battery). Wet the thumbs and place them on the
•
electrodes. A low clicking sound will appear near battery lid while you
click on the electrodes with one thumb.
Check that the chestbelt is positioned correct on test person and tight
•
enough. Check that the electrodes are wet. In hard cases it is necessary
to use a contact gel or a mixture of water with a few drops of washing-
up liquid. The level for HR signal can vary from person to person. Put
chestbelt on another known person who has a good pulse rendering.
Uneven heart rate.
Use an external unit for example a HR watch to check if it also indicates
irregular pulse. If this is the case, there is probably disturbance in the room.
Magnetic fields from high voltage cables, elevators, fluorescent tube etc.
can cause the disturbance. Other electronic equipment could be placed too
close. Move the bike to a different location in the room or change rooms. If
an irregular HR remains it should be checked manually If the HR remains
irregular at work the person's health should be examined.