background image

Monark 891 E/891 E Wingate Option

 7

Meter instructions

Batteries: 

 

   2 x 1.5 V, R6 (AA)

Storing temperature:           -10º C - +60º C
Operating temperature:          0º C - +50º C

Display

RPM

0-250

rev./min.

HR

50-240

bpm

TIME

0:00-99:59

min:sec

SPEED

0-99

km/h or mph

DISTANCE

0.0-99.9

km

FORCE

0.0-7.0

kp

Calories (CAL)

0-999

kcal

WATT

0.7 x RPM

watt

Press any key or move the pedal gives a signal to the 
meter that activates all functions.

At the display for heart rate (HR) a heart symbol is 
lit which means that the computer is trying to find a 
pulse signal from an external source (chestbelt with 
electrodes,  Art.  No:  9339-98  is  delivered  with  the 
ergometer).    If  the  meter  cannot  find  such  a  signal 
the HR function is automatically turned off after 30 
seconds.  When  the  function  is  turned  off  the  heart 
symbol  is  not  lit  any  more.  The  heart  rate  function 
can be turned on again by pressing a key.

The timer starts automatically when pedals are moved. 
Meter values for Time, Distance and Calories can be 
set  to  zero  by  pressing  the  RESET  button  for  more 
than two seconds.

The watt reading in the display is depending on the 
pedalling speed. The watts can accordingly be adjusted 
by increasing or decreasing the pedalling speed. 

Calories are calculated all the time. 

Features 891 E and 891 E Wingate Option

891 E

To receive the correct value for calories and watts the 
workload (kp) has to be set on the display. Kp value 
correspond to the total weight in the weight basket 
(weight of the basket, including the weights in it). 

Example: The workload is 2.1 kg (weight basket 0.1 
kg + 2 x 1 kg weight). Press the kp key to the left on 
the meter. Down in the display window figures is now 
flashing (kp). Increase or decrease in steps of 0.1 kp 
by pressing the kp button (up arrow) or the RESET 
button (down arrow) until the reading is corresponding 
with the actual or desired kp values (workload) from 
the  weight  basket.  After  that  press  the  CAL/WATT 
button to either show the CAL or WATT figures. At 
further press on the CAL / WATT-button the display 
toggles between calories and watts.

891 E Wingate Option

To get correct readings for calories and watts the kp 
value on the electronic meter has to be set to the same 
value as the workload that is the weight of the basket 
including  the  weights  in  it.  The  rubber  plates  are 
included in the calibrated weight of the 1 kg weight 
basket.

Example: The workload is 3 kg / 6.6 lbs (weight basket 
1 kg / 2.2 lbs + 2 x 1 kg / 1.1 lbs weight). Press the 
kp key to the left on the meter. Down in the display 
window figures is now flashing (kp). Increase in step 
by  0.1  with  kp  button  (up  arrow)  alt.  the  RESET 
button (down arrow) until the value is consistent with 
the weight basket, in this case 3.0. After that press the 
CAL/WATT button to either show the CAL or WATT 
figures. At further press on the CAL / WATT-button 
the display toggles between calories and watts.

Do not expose the meter to direct sunlight or extremely 
high  temperature.  Do  not  use  any  dissolvents  when 
cleaning. Use only dry cloth.

Summary of Contents for 891 E Wingate Option

Page 1: ...Monark 891 E and 891 E Wingate Option Manual for 891 E Art No 90891 891 E Wingate Option Art No 90891 2 ...

Page 2: ......

Page 3: ... 9 Adjustment brake cord tension 891 E 10 Adjustment brake cord tension 891 E Wingate Option 11 Troubleshooting guide 891 E 12 Troubleshooting guide 891 E Wingate Option 13 Service 16 Warning 16 Warranty 16 Service check and Maintenance 16 Batteries 17 Crank bearing 17 Flywheel bearing 17 Transportation 17 Replacement of brake belt 17 Brake belt contact surface 17 Chain 1 2 x 1 8 18 Freewheel spro...

Page 4: ...iving proof of precision reliability strength and service Those are the reasons why we are now the world leader in cycle ergometers and the market leader in Scandinavia in transport cycles We manufacture develop and market ergometers and exercise bikes transport bikes and specialized bicycles Our largest customer groups are within health care sports medicine public authorities industry and postal ...

Page 5: ...he publication Upper body fitness if you click on Sports Medical Tests and studies Tests Protocols NOTE Use of the product may involve considerable physical stress It is therefore recommended that people who are not accustomed to cardiovascular exercise or who do not feel completely healthy should consult a physician for advice NOTE The Astrand test is developed for leg ergometer Therefore these t...

Page 6: ...ial number 1 Fig Polarity Facts about 891 E Wingate Option Adjustable stand for optimal position The weight basket is released by a push button mounted on the cover Electronic meter with heart rate Powder painted Wheels for easy transport Width 700 mm 27 5 Length 1500 mm 22 Height 1660 mm 65 3 Weight Ergometer 26 kg 57 3 lb stand 35 kg 77 2 lb totally 61 kg 134 5 lb Delivered with 3 9 kg weights I...

Page 7: ...alue correspond to the total weight in the weight basket weight of the basket including the weights in it Example The workload is 2 1 kg weight basket 0 1 kg 2 x 1 kg weight Press the kp key to the left on the meter Down in the display window figures is now flashing kp Increase or decrease in steps of 0 1 kp by pressing the kp button up arrow or the RESET button downarrow untilthereadingiscorrespo...

Page 8: ...ob 2 Handle support stand A person s heart rate can be measured with a chest belt that senses the electronic output of the heart The chest belt is standard equipment Fuss free HR measurement requires that the belt is correctly placed When it is correctly fitted the logo on the belt will be central and readable outward and upright by another person Before putting on the belt clean the skin where th...

Page 9: ... it See Fig Adjustments Fig Workload adjustment 1 Release button Fig Settings 1 Disengagement knob 2 Handle support stand Fig Brake device 1 Stop 2 Cord bracket 3 Tension center 4 Return strap 5 Weight basket 6 DC connector 7 Data output Anaerobic tests 891 E Wingate Option Model 894 E has a computer for anaerobic testing and makes the bike possible to connect to an external PC PC cable is include...

Page 10: ...sion centre Lock the weight basket in its upper position with the stop 3 and after that loosen the lock washer 5 somewhat so that the cord length can be adjusted If the basket is too low shorten the belt somewhat If the basket is too high lengthen the cord somewhat Then lock the clamp again and check that the basket rises between 150 mm 5 9 and 190 mm 7 5 when the wheel is rotated NOTE To receive ...

Page 11: ... at the tension centre 3 Lock tension centre again in its upper locking position with the stop 1 and then release the lock brace 2 for the brake line so that its length can be adjusted If the basket is too low shorten the belt somewhat If the basket is too high lengthen the cord somewhat Tighten the bracket again and release and check if the measurements above are OK when the flywheel is rotated b...

Page 12: ...s scratching There is a click noise and a squeak noise when pedalling Loosen the chain No heart rate displayed Check the chestbelt battery Wet the thumbs and place them on the electrodes A low clicking sound will appear near battery lid while you click on the electrodes with one thumb Check that the chestbelt is positioned correct on test person and tight enough Check that the electrodes are wet I...

Page 13: ...dvice how to check sensors of magnetic type 1 Unplug the sensor on bikes circuit board 2 In the jack in the end of sensor cable measure with a summer or an ohmmeter then angle the magnet in near of the sensor A signal should be heard or value approx 0 ohm displayed on ohm meter No heart rate displayed Check the chestbelt battery Wet the thumbs and place them on the electrodes A low clicking sound ...

Page 14: ...reen LED on the COM port tester should light up This will indicate that the bike s circuit board is powered on 4 When the weight basket is hoisted up the red LED on the tester flash briefly The same thing will happen when the weight basket is dropped again 5 When a person starts to pedal the bike the red LED on COM port tester will flash in the same tact as the RPM If all expected flashes could be...

Page 15: ...ections on Circuit board Connector U Sensor 1 Connector F Sensor 2 Connector R Sensor on flywheel Connector Power supply red black wire Connector M Magnet Connector RS232 Communication cables 5 pcs Connector 1MS Button to release the weight basket Fig COM port tester Troubleshooting guide 891 E Wingate Option ...

Page 16: ...and flywheel are working normally and that no abnormal play or sound exists I e play in bearings causes fast wearing and with that follows a highly reduced lifetime Check that the flywheel is placed in the center and with plane rotation Service Warning Make sure the voltage indicated on the appliance corresponds to the local mains voltage before making connections Warranty EU countries Private use...

Page 17: ... cord from the bike When assembling a new brake cord first enter one end into the hole in the tension center and tie a knot and let the knot fall into the bigger part of the hole Lock the end of the cord with the lock washer Brake belt contact surface Deposits of dirt on the brake belt and on the contact surface may cause the unit to operate unevenly and will also wear down the brake belt The cont...

Page 18: ...d Loosening or tightening the nuts on the chain adjusters 1 will then move the hub and axle forward or backward Then tighten the nuts on the hub axle again See Fig Chain adjustments Toreplacethechain loosenthechainadjustersasmuch as possible Dismantle the chain lock 6 and remove the chain Use a pair of tongs for dismantling spring Put on a new chain and assemble the chain lock The spring of the ch...

Page 19: ... place the spacer and axle nut outside See Fig Special remover NOTE NOTE Do not tighten the axle nut completely It must be possible to loosen the adapter sprocket half a turn Replace sprocket adapter and assemble the new parts in reverse order according to the above The sprocket should be lubricated with a few drops of oil once a year Tilt the cycle to make it easier for the oil to reach the beari...

Page 20: ...vice complete 10 1 9145 71 Handle pair 36 1 9391 61 Frame cover left 11 2 9371 71 Handcover 37 1 9391 141 Instrument cover 12 1 9300 450 Steel crank set complete 38 2 5675 9 Screw 13 1 9326 164 Magnet 39 1 9391 3 Flywheel with freewheel sprocket 14 1 9391 55 Plastic cap black 40 1 9000 14 Spacer 5 mm 15 1 8966 175 BB cartridge bearing complete 41 1 9300 17 Spacer 23 mm 16 1 9391 44 Knob 42 1 9000 ...

Page 21: ...on 21 Spare Parts List 891 E and 891 E Wingate Option Pos Qty Art No Description Pos Qty Art No Description 1 1 9391 80 Table stand complete height adjustable 3 2 9000 29 Transport wheel complete 2 1 9391 9 Upper part 1 9391 8 10 Screw set ...

Page 22: ... 37 Holder 9 1 5767 9 Nut M5 33 1 9384 34 Magnet plate 10 1 9384 35 Stop screw M5x30 34 1 14303 Screw M5x13 11 2 9127 37 Spacer 8 5x12 L 13 35 1 9384 32 Electro magnet 12 2 19088 6 Ball bearing 608 2z 36 1 9384 31 Magnet bracket 13 2 9374 37 Magnet 37 3 5673 9 Screw M5x12 14 2 5862 Washer 6x19x1 38 1 5670 Screw M4x10 15 1 9324 70 Self locking cap 39 1 9324 25 Weight basket 16 3 14323 Screw M6x16 4...

Page 23: ...326 166 Holder for sensor 32 1 9391 141 Instrument cover 10 1 9145 71 Handle pair 33 2 5675 9 Screw M5x6 5 11 2 9371 71 Handcover 34 1 9391 3 Flywheel with freewheel sprocket 12 1 930 450 Steel crank set complete 35 1 9000 12 Chain adjuster pair 13 1 9326 164 Magnet 36 1 9300 12 Spacer 23 mm 14 1 9391 55 Plastic cap black 37 1 9000 15 Locking ring SgH 028 15 1 8966 175 BB cartridge bearing com ple...

Page 24: ...KROONS VÄG 1 SE 780 50 VANSBRO SWEDEN WWW MONARKEXERCISE SE TEL 46 0 281 59 49 40 FAX 46 0 281 719 81 Version 1301 Art No 7950 310 ...

Reviews: