Monark Cardio Care 827 X
11
Ser
vice
Connection
The exercise bike is powered with the supplied
wall adaptor. The small round connector at the
end of the adaptor cord is put into the bike con-
nector located at the far back on the left cover.
Replacement of brake belt
Loosen the belt tension as much as possible.
Remove the left cover. Loosen the brake belt at
both ends and replace with a new one.
See fig: Brake belt.
Assamble the bike in reverse order.
NOTE: When replaceing the brake belt it is re-
commended to clean the brake surface. See
”Brake belt contact surface”.
Crank bearing
The crank bearing is long term greased and needs
normally no supplementary lubrication. If pro-
blem arises, please contact your Monark dealer.
Flywheel bearing
The bearings in the flywheel are lifetime greased
and require normally no maintenance. If problem
arises, please contact your Monark dealer.
Brake force spring adjustment
After a service where the bike has been taken
apart, partly or completely, and put together
again, the following check should be performed
to be sure the workload is adjusted according to
the display.
Remove the left cover, if not already done.
Connect power adaptor. On the console adjust
WATT to level 2 (LOAD 2). The spring should
now be hanging straight but not streched.
If spring is too long or too short adjust with the
adjustment screw at the other end of the brake
belt until correct state is reached. See fig. Spring,
adjustment screw. Lock the adjustment screw and
put on the cover again. The bike is now ready for
use.
NOTE that 827 X is an exercise cycle that can’t
be calibrated. It is not for testing when the dis-
play just shows an estimate value.
Fig: Spring,
adjustment screw
1) Spring
2) Adjustment screw
1
2
Fig: Brake belt
1,2) Loosen hooks
1
2
Summary of Contents for cardio care 827 x
Page 1: ...Manual English Svensk Monark 827 X Cardio Care 827 X...
Page 2: ......
Page 18: ...Notes...
Page 34: ...Anteckningar...
Page 35: ......