equipment details
56
equipment details
57
trumatIc e2400
trumatic e 2400 L.p.G. Heater with
electronic control, built-in air distribution
and thermostat
operating instructions
Always observe the operating instructions and
‘Important operating notes’ prior to starting!
The vehicle owner is responsible for the correct
operation of the appliance!
The installer or vehicle owner must apply the
yellow sticker with the warning information,
which is enclosed with the appliance, to a place
in the vehicle where it is clearly visible to all
users (e.g. on the wardrobe door)! Ask Truma to
send you stickers, if necessary.
control panel with sliding switch
a Slide valve
Heating – Off – Ventilation
b Slide valve for high setting (large flame
symbol) and low setting (small flame symbol)
control panel with rotary switch
c ‘Heating’ rotary switch high setting
(large flame symbol) and low setting
(small flame symbol)
d ‘Off’ rotary switch
e ‘Ventilation’ rotary switch high setting (large
symbol) low setting (small symbol)
Switching on the Heating
1. Remove cowl cap.
2. Turn on gas cylinder and open quick-acting
valve in the gas supply line.
3. Adjust desired room temperature at
rotary knob.
4. Switching the heating on:
control panel with sliding switch:
Set the switch (a) to Heating and switch (b) to
the desired output setting.
control panel with rotary switch:
Set the rotary switch to the desired output
setting (c). If the outside temperature is low,
switch to high setting.
The Trumatic E heater has been tested and
approved for operation, also when the vehicle
is moving. The burner with fan assistance
guarantees satisfactory operation, even
under extremely windy conditions. It may be
necessary to observe respective, country-
specific regulations for the operation of liquid
gas appliances when the vehicle is moving.
Switching on the ventilation
control panel with sliding switch:
Set switch (a) to Ventilation and switch (b) to
the desired output setting.
control panel with rotary switch:
Set the rotary switch to the desired output
setting (e).
Switching off
repairs
Repairs should only be carried out by qualified
personnel, as otherwise the warranty will be
void. Only original Truma parts are to be used.
de-scaling
Introduce wine vinegar into the water system
and allow time for it to react with the scale.
Flush out thoroughly with fresh water.
Hygiene
The water tank in the water heater Is made of
high quality stainless steel. However. to avoid
micro-organism colonization of the tank, it
should be heated to 70ºC with the electrical
heater at regular intervals. Do not drink water
from the hot taps.
fuses
The water heater fuse is on the electronic
control unit on the water heater.
note: only replace the miniature fuse on
the p.c.b. with a fuse of the same type:
1.25 at en 60127-2-3 (slow action).
General safety notes
If the gas system is leaking or if there is a
smell of gas:
• Extinguish all naked flames.
• Do not smoke.
• Switch off the appliances.
• Shut off the gas cylinder.
• Open the windows.
• Do not actuate any electrical switches.
• Have the entire system checked by an expert.
1. Repairs may only be carried out by an expert.
2. The following will invalidate the guarantee:
a) Any alteration to the appliance.
including the cowl.
b) The use of non-original Truma
parts/accessories.
c) Non-observance of the
Operating Instructions.
3. The operating pressure for the gas supply
is 30 mbar and must correspond to the
operating pressure of the appliance (see
data plate).
Liquid gas systems must comply with the
technical and administrative regulations of
the respective country of use (e.g. en 1949
for vehicles in europe).
a qualified technician must inspect/test
according to en 1949 every two years and a
certificate issued.
The vehicle owner is always responsible for
arranging the inspection.
4. Do not operate the water heater when
refuelling the vehicle and when in the garage.
5. During the initial operation of a brand new
appliance (or after it has not been used for
some time), a slight amount of fumes and
a certain smell may be noticed for a short
while. Remedial action is to immediately
run the heater at maximum output and to
ensure adequate room ventilation.
6. If the burner makes an unusual noise or if the
flame lifts off, it is likely that the regulator is
faulty and it is essential to have it checked.
technical data
water contents:
10 Iitres
water pressure:
up to max. 2.8 bar
type of gas:
Liquid gas (propane/butane)
operating pressure:
30 m/b
rated thermal output:
1500 W
Gas consumption:
120 g/h
Heating time up to approx. 70ºc:
Gas operation: approx. 35 minutes
Electrical operation: approx. 70 minutes
Gas and electrical operation: approx 20 minutes.
power consumption 12 v
Ignition: 0.17 A
Heating up: 0.08 A
Standby: 0.04 A
power consumption 230 v
Heating up: (2 A) 450 W
Weight (empty): Approx: 6.7 kg
Summary of Contents for HB095 2008
Page 4: ......
Page 10: ...motorhome code Code of conduct 10 The Country code 12 The Coastal code 12 ...
Page 17: ... en route Panel van spare wheel detail 20 ...
Page 18: ... En route 20 Panel van spare wheel detail Please refer to the Fiat handbook ...
Page 22: ...arrival at site Positioning the motorhome 26 ...
Page 32: ...Connecting services 42 ...
Page 38: ...Electrical systems 52 ...
Page 66: ...Equipment details 106 ...
Page 71: ...Motorhome Care 114 ...
Page 72: ...useful information Owners club aftercare 116 Useful contacts 117 Change of ownership 118 ...