equipment details
84
equipment details
85
unusual noises
fauLt
poSSIBLe cauSe
remedy
Loud humming
A component of the refrigerant circuit cannot move freely
(touching the wall)
Foreign body jammed between the cooling unit and the wall
Fan noise
Bend the component carefully away
from the obstruction
Remove the foreign body
compressor is not running (connected to ac supply)
fauLt
poSSIBLe cauSe
remedy
No voltage
Interruption in the supply cable
Main switch faulty (if installed)
Additional supply line fuse has blown (if installed)
Establish a connection
Replace the main switch
Replace the supply line fuse
Voltage is present but the
compressor doesn’t run
Ambient temperature too high
Insufficient ventilation and/or air supply
Condenser is dirty
Move the refrigerator to another location
Clean the condenser
Electric circuit between the pins in
the compressor interrupted
Defective compressor
Replace the compressor
poor cooling, interior temperature increases
Compressor runs for a long time/
continuously
Ambient temperature too high
Insufficient ventilation and/or air supply
Condenser is dirty
Faulty fan
Move the refrigerator to another location
Clean the condenser
Replace the fan
Compressor runs intermittently
Battery capacity exhausted
Charge the battery
Summary of Contents for HB095 2008
Page 4: ......
Page 10: ...motorhome code Code of conduct 10 The Country code 12 The Coastal code 12 ...
Page 17: ... en route Panel van spare wheel detail 20 ...
Page 18: ... En route 20 Panel van spare wheel detail Please refer to the Fiat handbook ...
Page 22: ...arrival at site Positioning the motorhome 26 ...
Page 32: ...Connecting services 42 ...
Page 38: ...Electrical systems 52 ...
Page 66: ...Equipment details 106 ...
Page 71: ...Motorhome Care 114 ...
Page 72: ...useful information Owners club aftercare 116 Useful contacts 117 Change of ownership 118 ...