Technical service manual
21
UK
“THE MACHINE DOES NOT PERFORM THE WHEEL SPIN WHEN the
START BUTTON IS PRESSED and/OR THE GUARD IS LOWERED”
In this case the various causes can be identified on the basis of the information on the
displays.
1) The displays continue to display the imbalance values calculated previously.
The motherboard is not receiving or not “hearing” the START signal from the keyboard
or microswitch.
Check:
- that the automatic start microswitch associated to the wheel guard is operating cor-
rectly (when the guard is lowered the switch contact must be closed);
- that the cam which trips the automatic start device microswitch is set correctly;
- that the automatic start microswitch is wired correctly;
- that the START key is operating correctly.
If the checks listed above do not reveal faulty components, replace the motherboard.
2) The displays show the wheel’s geometrical data.
The motherboard is receiving the signal from the START button or microswitch, but the
resulting command is not being given.
Check:
- that the “control cable” connecting the motherboard to the “power supply and con-
trol” circuit board is connected and wired correctly;
- that the “power supply and control” circuit board is operating correctly;
- that the wheel spin motor is in good working order.
If the checks listed above do not reveal faulty components, replace the motherboard.
3) The displays show the message “Cr Err”.
The contact of the microswitch associated to the guard is open.
Check:
- that the guard is lowered when a wheel spin is performed (by pressing the START
button);
- that the automatic start microswitch associated to the wheel guard is operating cor-
rectly (when the guard is lowered the switch contact must be closed);
If the checks listed above do not reveal faulty components, replace the motherboard.
4) The displays show the message “Err 30
If abnormal noise is noted, check the condition of the roller or the setting of the wheel
spin device.
If the wheel is rotated, check operation of the encoder circuit board, see “Service Pro-
grams”.
If on the other hand the motor does not start:
- check the motor fuse on the Peac FU1 circuit board;
- check that the motor power supply cable is connected correctly;
- check operation of the PEAC circuit board;
- check operation of the motor.
Summary of Contents for MT 2450
Page 1: ...MT 2450 Code 4 131046_uk 12 2013 Technical service manual...
Page 25: ...Technical service manual 25 UK Note...
Page 27: ...Technical service manual 27 UK...
Page 28: ...28 Technical service manual...
Page 29: ...Technical service manual 29 UK Cod 4 101700...
Page 30: ...30 Technical service manual...
Page 31: ...Technical service manual 31 UK...
Page 32: ...32 Technical service manual...
Page 33: ...Technical service manual 33 UK Cod 457674B...
Page 34: ...34 Technical service manual...