Startline S 424-S 421-S 521-S 524
Operator manual
99
UK
Before proceeding with the electrical and
pneumatic connection and whenever the
electrical and pneumatic power supply is
restored, make sure that the machine is in
the configuration
described below:
- pedal A COMPLETELY LOW
(turntable E closed).
ONLY FOR VERSIONS WITH TILTING POLE:
- pedal B COMPLETELY LOW
(pole C not tilted).
DANGER
1.2.d TECHNICAL DATA
- Turntable locking
Startline S 421 - Startline S 521
- internal .......................................................................................................... from 12” to 23”
- external ......................................................................................................... from 10” to 21”
Startline S 424 (standard position) - Startline S 524
- internal .......................................................................................................... from 14” to 28”
- external ......................................................................................................... from 12” to 26”
-Power supply voltage
- single-phase ..................................................................................115-230±10%Volt 50/60Hz
- three-phase ...................................................................................230-400±10%Volt 50/60Hz
- DV .................................................................................................. 230±10%Volt 1ph 50/60Hz
- Rim width - Startline S 421 - Startline S 424 .................................................. from 4” to 13”
- Rim width - Startline S 521 ............................................................................. from 4” to 14”
- Rim width - Startline S 524 ............................................................................. from 4” to 16”
- Maximum wheel diameter - Startline S 421 ..................................................940 mm (37”)
- Maximum wheel diameter - Startline S 521 - Startline S 524 .....................1120 mm (44”)
- Maximum wheel diameter - Startline S 424 .................................................1250 mm (49”)
- Maximum opening of bead breaker Startline S 424 - S 421 - S 521: 75 mm (3”) / 330 mm (13”)
- Maximum opening of bead breaker Startline S 524: ............100 mm (4”) / 400 mm (16”)
-Bead breaking force ..................................................................... 15000 N (pressure 10 bar)
- Operating pressure ..................................................................................................8 - 10 bar
- Air consumption (TI version .................................180 Nl/min (average) 764 Nl/min (max)
- Air consumption (NON-TI version .......................155 Nl/min (average) 520 Nl/min (max)
- Weight - Startline S 521 ................................................................295 kg (310 kg TI version)
- Weight - Startline S 421 .................................................................................................223 kg
B
A
C
Summary of Contents for Startline S 421
Page 64: ...64 Startline S 424 S 421 S 521 S 524 Manuale Operatore Montaggio...
Page 77: ...Startline S 424 S 421 S 521 S 524 Manuale Operatore 77 I 18 SCHEMA ELETTRICO GENERALE...
Page 78: ...78 Startline S 424 S 421 S 521 S 524 Manuale Operatore...
Page 79: ...Startline S 424 S 421 S 521 S 524 Manuale Operatore 79 I...
Page 81: ...Startline S 424 S 421 S 521 S 524 Manuale Operatore 81 I Note...
Page 144: ...144 Startline S 424 S 421 S 521 S 524 Operator manual Mounting...
Page 157: ...Startline S 424 S 421 S 521 S 524 Operator manual 157 UK 18 GENERAL WIRING DIAGRAM...
Page 158: ...158 Startline S 424 S 421 S 521 S 524 Operator manual...
Page 159: ...Startline S 424 S 421 S 521 S 524 Operator manual 159 UK...
Page 161: ...Startline S 424 S 421 S 521 S 524 Operator manual 161 UK Notes...
Page 224: ...224 Startline S 424 S 421 S 521 S 524 Manuel Op rateur Montage...
Page 237: ...Startline S 424 S 421 321 S 524 Manuel Op rateur 237 F 18 SCH MA LECTRIQUE G N RAL...
Page 238: ...238 Startline S 424 S 421 S 521 S 524 Manuel Op rateur...
Page 239: ...Startline S 424 S 421 321 S 524 Manuel Op rateur 239 F...
Page 241: ...Startline S 424 S 421 321 S 524 Manuel Op rateur 241 F Notes...
Page 304: ...304 Startline S 424 S 421 S 521 S 524 Bedienungsanleitung Montage...
Page 317: ...Startline S 424 S 421 S 521 S 524 Bedienungsanleitung 317 D 17 ALLGEMEINGER SCHALTPLAN...
Page 318: ...318 Startline S 424 S 421 S 521 S 524 Bedienungsanleitung...
Page 319: ...Startline S 424 S 421 S 521 S 524 Bedienungsanleitung 319 D...
Page 321: ...Startline S 424 S 421 S 521 S 524 Bedienungsanleitung 321 D Anmerkungen...
Page 384: ...384 Startline S 424 S 421 S 521 S 524 Manual Operador Montaje...
Page 397: ...Startline S 424 S 421 S 521 S 524 Manual Operador 397 E 18 ESQUEMA EL CTRICO GENERAL...
Page 398: ...398 Startline S 424 S 421 S 521 S 524 Manual Operador...
Page 399: ...Startline S 424 S 421 S 521 S 524 Manual Operador 399 E...
Page 401: ...Startline S 424 S 421 S 521 S 524 Manual Operador 401 E Notas...