58D56002
21
PIL
OT
OFF
REMO
TE C
ONTROL
FLAME APPEARANCE
CHECKING BURNER FLAME
In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
The left and right rear flames should be yellow and extend 1"-2" above middle logs. The yellow flames should
not
contact
the logs. There should be glowing embers on the front surface of the middle log.
Note: The flames and embers will be
an opaque orange color during the burn off time.
Figure 21 - Correct Flame Appearance
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns.
Do not allow fans to blow directly into the stove. Do not place
a blower inside the burn area of the stove. Ceiling fans may create drafts that alter flame patterns. Sooting and improper
burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or
bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during
the initial operation of the appliance, possibly causing headaches or eye or lung irritation.
This is a normal and temporary
occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventila-
tion by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight
and will disappear with continued use.
Middle Log
Middle Log
Summary of Contents for CSVF20SNV
Page 30: ...30 58D6002 NOTES ...
Page 31: ...58D56002 31 NOTES ...