Check Gas Pressure
The heater gas inlet connection is 3/8" NPT at the valve. The
inlet is located on left side of stove. Remove front control
plate to better access the inlet.
When tightening up the joint to the valve, hold the valve securely
with a wrench to prevent movement.
Test all gas joints from the gas meter to the heater valve for
leaks using a gas analyzer or soap and water solution after
completing connection.
DO NOT USE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the
control set to
HIGH.
Millivolt ControL -
Figure 10
The valve regulator controls the burner pressure which should
be checked at the pressure test point.
If outlet pressure is low, check inlet pressure against data
plates or manual.
Turn captured slotted screw counter clockwise 2 or 3 turns
and then place tubing to pressure gauge over test point (Use
test point “OUT” closest to control knob). After taking pressure
reading, be sure and turn captured screw clockwise firmly to
re-seal. Do not over torque. Check for gas leaks.
NOTE:
Remove control panel to access gas valve.
Connect Remote Receiver
1. Remove cover on control panel to show opening for
remote receiver. Figure 11
2 Follow remote receiver Instructions to make all necessary
wiring connections.
3. Place remote receiver in the opening of control panel.
Use two screws provided to attach remote receiver to the
control panel. Figure 11
NOTE:
Do not place remote in combustion chamber.
FP2781
millivolt valve
Test Port "OUT"
Figure 10 - Pressure Test Point Location Millivolt Control
Connecting directly to an unregulated propane/L.P.G.
tank can cause an explosion.
WARNING
!
O
N
O
FF
ST1175
remote receiver
Remote
Receiver
Cover
Figure 11 - Install Remote Receiver