Unvented Cast Iron Gas Stoves
18
3-90-58D6002
Monessen • Concorde VF Installation Manual_R11 • 02/17
MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
1.
STOP!
Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device
(piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for
“Match Lighting Instructions,” Page 20.
4. Turn gas control knob clockwise
to the OFF
position, and turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP!
Follow “What to Do if You Smell Gas,” page 18. If you
don't smell gas, go to next step.
6. From OFF position, turn the gas control knob
counterclockwise
to IGN position. Push in
control knob for 5 seconds.
NOTE: If you are running the heater for the first time,
it will be necessary to press in the control knob for
30 seconds to allow air to bleed out of the gas piping.
TO TURN OFF GAS TO HEATER
Pilot
Control Cover Plate for Millivolt
ST1178
control cover plate
Hi/Lo Control
Ignitor/Pilot Control
OFF
ON
ST1179
on off switch
On/Off Switch
(Located on Side of Stove)
7. With the control knob pushed in, push in and release
the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 10
seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release
the control knob.
9. Turn gas control knob counterclockwise
to the
ON position.
10. After the pilot has been lit for one minute, the burners
can be turned on. Turn the ON/OFF switch to ON
position.
11. If the gas logs will not operate, follow the instructions
“To Turn Off Gas To Heater” below and call your
service technician or gas supplier.
3. If applicable: Turn off all electric power to the
heater.
1. Turn ON/OFF switch to OFF position.
2. Turn control knob clockwise
to OFF position
to completely shut off the heater.