56D0106
19
Figure 16 - Vent Opening Requirements
Note: Horizontal runs of vent
must be supported every three
feet (914mm). Use wall straps
for this purpose.
Figure 17 - Rigid Vent Pipe Connections
Female
Locking Lugs
Male Slots
REAR WALL VENT INSTALLATION
When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind
the appliance
• The maximum horizontal distance between the rear of the appliance and the outside of termination is 20" (508 m).
See
Figure 15.
• Only one 45° elbow is allowed in these installations.
VENTING INSTALLATION
1. Locate and cut the vent opening in the wall. For
combustible walls first frame in opening.
See
Figure 16.
Combustible Walls:
Cut a 9
1
⁄
2
"H x 9
1
⁄
2
" W
(241mm x 241mm) hole through the exterior wall
and frame as shown.
See Figure 16.
Noncombustible Walls:
Hole opening should be
7
1
⁄
2
" (190mm) in diameter.
2. Rigid vent pipes and fittings have special twist-lock
connections. Assemble the desired combination of
pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor.
Twist-lock Procedure:
The female ends of the
pipes and fittings have three locking lugs (indenta-
tions). These lugs will slide straight into matching
slots on the male end of adjacent pipes and fittings.
Push the pipe sections together and twist one sec-
tion clockwise approximately one-quarter turn
until the sections are fully locked.
See Figure 17.
3. Attach vent pipe assembly to the fireplace. Set
fireplace in front of its permanent location to insure
minimum clearances. Mark the wall for a 9
1
⁄
2
"H
x 9
1
⁄
2
"W (241mm x 241mm) rectangle hole (for
noncombustible material such as masonry block or
concrete, a 7
1
/
2
" [190mm] diameter hole is accept-
able).
See Figure 16.
The center of the hole should
line up with the center line of the horizontal rigid
vent pipe end. Be sure to allow for minimum rise.
Cut a 9
1
/
2
"x9
1
/
2
" (241mm X 241mm) rectangle hole through combustible exterior wall (7
1
/
2
" [190mm] diameter hole if
noncombustible). Frame as necessary. Allow
1
/
4
" minimum rise per foot.
See Figure 16.
Figure 15 - Rear Vent Application,
Maximum Horizontal Distance
Top View Flat Installation
Summary of Contents for SDV500
Page 46: ...46 56D0106 1 2 3 11 6 7 8 5 4 9 10 ILLUSTRATED PARTS LISTS FIREBOX COMPONENTS ...
Page 48: ...48 56D0106 1 2 3 6 4 5 ILLUSTRATED PARTS LISTS ADDITIONAL ACCESSORIES ...
Page 52: ...52 56D0106 ILLUSTRATED PARTS LISTS 1 2 3 4 5 6 7 9 ELECTRONIC IGNITION 8 10 11 L O HI ...