20
32D1999
W
ARNING
OPERATING INSTRUCTIONS
SAFTEY INSTRUCTION FOR MANUAL CONTROL WITHOUT PILOT
A.
BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not attempt to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
B.
Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in
or turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may
result in a fire or explosion.
C.
Do not use this appliance if any part of it has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas control that
has been under water.
1. STOP! Read the safety information label.
2. WARNING: BE SURE THE CHIMNEY DAMPER IF FULLY OPEN.
3. Make sure the manual shutoff valve is fully open, and the gas contol valve is fully off.
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow “B” in the safety information label. If you don't smell gas, go to next step.
5. Place a burning match on the surface of the burner embers (granules). Do not hold the match in hand.
Slowly turn the manual valve counterclockwise
to “ON”.
6. If the burner does not light before the match goes out, immeadiately turn the manual valve clockwise
to “OFF”.
FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instruction
exactly, a fire or explosion may result
causing property damage, personal
injury or loss of life.
W
ARNING
1. Turn the manual valve clockwise
to “OFF.”
MATCH LIGHTING INSTRUCTIONS
MANUAL CONTROL LIGHTING INSTRUCTIONS