5
VFC Vent Free Fireplace System
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
PRODUCT FEATURES
OPERATION
This unvented gas heater requires no outside venting
and burns cleanly with excellent heating efficiency. As a
zero-clearance appliance, it can be installed against (or
recessed into) any wall that is accessible to a gas line.
Piezo Ignition
Fireplace
Screen
Control Knobs
Figure 1.
VFC Shown with Control Access Door Open
On/Off Switch
GAS PRESSURES
Control
Fuel
Millivolt and IPI
Regulator Pressure
Nat.
3.5" w.c.
Pilot Regulator
Nat.
3.5" w.c.
Max. Inlet Pressure
Nat.
10.5" w.c.
Min. Inlet Pressure
Nat.
5.0" w.c.
Regulator Pressure
LP
10.0" w.c.
Max. Inlet Pressure
LP
13.0" w.c.
Min. Inlet Pressure
LP
11.0" w.c.
GAS SPECIFICATIONS AND ORIFICE SIZES
NOTE:
For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.
MODEL
FUEL CONTROL
MAX
BTU
MIN
BTU
ORIFICE
SIZE
VFC24CNV NAT MILLIVOLT 22,000 16,000 2.35mm
VFC24CPV
LP
MILLIVOLT 22,000 20,000 1.45mm
VFC24CNI
NAT
IPI
22,000 16,000 2.35mm
VFC24CPI
LP
IPI
22,000 20,000 1.45mm
VFC24LNV NAT MILLIVOLT 22,000 16,000 2.35mm
VFC24LPV
LP
MILLIVOLT 22,000 20,000 1.45mm
VFC24LNI
NAT
IPI
22,000 16,000 2.35mm
VFC24LPI
LP
IPI
22,000 20,000 1.45mm
VFC32CNV NAT MILLIVOLT 28,000 19,000
#38
VFC32CPV
LP
MILLIVOLT 27,000 22,000
#52
VFC32CNI
NAT
IPI
28,000 19,000
#38
VFC32CPI
LP
IPI
27,000 22,000
#52
VFC32LNV NAT MILLIVOLT 28,000 19,000
#38
VFC32LPV
LP
MILLIVOLT 27,000 22,000
#52
VFC32LNI
NAT
IPI
28,000 19,000
#38
VFC32LPI
LP
IPI
27,000 22,000
#52
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Millivolt and EcoLogic
®
2.0 controls have four (4)
positions:
OFF
- All gas to the gas logs is shut off at the
valve.
IGN
- Valve position to light/maintain a standing
pilot.
ON
- Valve position to turn ON/OFF log set with
remote switch/thermostat.
LOW/HI
- Variable position to control flame height
(heat output).
PILOT
The gas log heater is fitted with a specially designed safety
pilot light (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be re-lit when adequate fresh air
is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt generator
to provide power for remote activation.