Compact Hopper Test Box Instructions TSP063doc Issue 2.1 – June 2004
©
Money Controls 2004. All rights reserved.
Page 6 of 11
3.1
Test Box Functions
The following are the functions available for this test box.
3.1.1 CONT / PULSE
Select mode for paying out coins either continuously (“CONT”) or pulsed (“PULSE”).
In continuous mode the coins are ejected without any pause.
In pulsed mode the motor pauses for 500ms between each coin ejection.
3.1.2 FREE / COUNT
“FREE” pays out the coins until hopper is empty,
“COUNT” pays out number of coins selected using the “COUNT” switch
3.1.3 HOPPER / ON
Start and stop the Hopper. This shuts the power off to the Hopper motor but not the test
box.
3.1.4 COUNT SWITCH
Rotate to select a predefined number of coins to be dispensed.
3.1.5 OPTO LED
Illuminates each time a coin is dispensed and remains lit when the opto is blocked
3.1.6 OPTO TEST / START COUNT
While the Hopper is off, pressing this button will test the opto and confirm by illuminating
the “OPTO LED” and by incrementing the counter by 1.
If the Hopper is powered up, this will start the payout of coins in
Pulsed Mode
.
3.1.7 DISPLAY SCREEN
The display shows the counter on the left side of the screen and the motor current on the
right.
N.B.– each time the Hopper is started the counter is reset.