18.2 Token Selection “Rotary switch positions 0 to 5 & C”
Positions 1 to 5 and C select the token to accept. Position 0 disables all tokens. The switch
position is read at power-up or reset, but may be changed at any time by pressing the push
button for at least 1 second.
18.3 Routing replication “Rotary switch position 6”
Position 6 allows a ccTalk 1:1 ribbon cable to connect a SR5i to another 5 inch ccTalk
validator and copy the EEPROM sorter path configuration. Power should be applied through
the parallel connector on SR5i and then only the ccTalk cable used to connect the two
products. All 4 routes for all 16 coins are replicated.
18.4 Power-up Diagnostics “Rotary switch position 7”
Position 7 controls whether SR5i checks the sensor and thermistor readings at power-up for
an out-of-range error. If a fault condition is detected then no coins can be accepted.
18.5 Debugging “Rotary switch position 8”
Position 8 allows the solenoid test sequence to be enabled - pulsed solenoid duty cycle is
500ms on, 500ms off.
If the sorter is enabled on the SR5i then the software cycles through a solenoid test
sequence…
[ Accept Gate ]
Æ
[ Lower Sorter Flap ]
Æ
[ Upper Sorter Flap ]
Æ
[ Manifold Flap ]
Æ
If the sorter is disabled the only the accept gate solenoid is pulsed.
[ Accept Gate ]
Æ
[ Accept Gate ]
Æ
[ Accept Gate ]
Æ
[ Accept Gate ]
Æ
18.6 EEPROM route programming “Rotary switch position 9”
Position 9 allows the sorter routing to be programmed to the default state or set by an
external routing plug.
Reset to default: Enables all the sorter routes in EEPROM to be changed to the default
sorter route (usually 5).
Swallow plug: Allows a routing plug to be copied or ‘swallowed’ to EEPROM. Once this is
done, the routing plug can be removed and the coins will be routed in an identical manner.
The legacy routing plug allows any of 7 coins to be routed to 3 paths ( in the order D then C
then B ). This function also programs the default sorter path for coin 8 and copies the paths
from the lower bank to the upper bank (coins 1..8 to 9..16).
If both switches are up then the plug swallowing has priority.
The sorter must be enabled ( factory option ) for these functions to work.