background image

 

4. FUNCTIONS OF CONTROLS AND 
INDICATORS

 

 
The functions of the items on the display panel are described below:  
 

Key switch

 - Used to release the magnetic lock by momentarily turning the key clockwise. The 

key cannot be removed in this released position. 
 

Red Lamp -

 Indicates that the door is open. (Controlled by the internal door contact switch.) 

 

Green Lamp

 – Indicates that the door is secured (controlled by the internal magnetic bond 

sensor switch.) 
 

Amber Lamp - 

Indicates that the door is not secure (controlled by the internal magnetic bond 

sensor switch and the control module in the SIC). When flashing, indicates that the push bar has 
been pressed and that the countdown timer (typically set to 15 seconds) has been activated. 
 

Audible Alarm

 - When sounding continuously indicates that the tamper switch within the CC-

8946 has opened. (controlled by the internal tamper switch and by the control module in the 
SIC.) When sounding on-and-off indicates that the push bar has been pressed and that the 15 
second count down timer has been activated. When sounding continuously indicates that the 
unit’s cover has been opened. 
 

Test switch

 - When pressed illuminates all three indicator lamps and sounds the audible alarm 

and the corresponding items on the Control Module in the SIC. (Accessed using a paper clip or 
similar item through the small hole located near the center of the underside of the Display Panel.) 

Summary of Contents for CC-8946

Page 1: ...INSTRUCTION MANUAL Model CC 8946 Rev 04 16 Magnetic Lock with Display Panel Moniteq Inc...

Page 2: ...Rev 1 1 Magnetic Lock with Display Panel Table of contents 1 Introduction 3 2 Specifications 4 3 Supplied equipment 5 4 Functions of controls and indicators 6 5 Installation 7 6 Operation 12 7 Theory...

Page 3: ...r magnetic bond and door contact switches are used to provide output status signals All connections to the CC 8946 are made via an attached 20 ft cable The integration of the display panel with the ma...

Page 4: ...laceable LEDs Key switch Medico high security cylinder w two keys Internal Functions Tamper switch Magnetic door contact switch Dual Magnetic bond sensing switches Piezo electric audible alarm Lamp al...

Page 5: ...header to secure the door and display the door status 1 Magnetic Armature Mounts on the door so as to align with and bond to the magnetic lock when the door is secured 1 Mounting Template Used to accu...

Page 6: ...indicates that the push bar has been pressed and that the countdown timer typically set to 15 seconds has been activated Audible Alarm When sounding continuously indicates that the tamper switch withi...

Page 7: ...embly mounts firmly and rigidly to the underside of the header on the stop side of the door The armature mounts to the face of the door with special hardware for proper floating action to assure total...

Page 8: ...hat the spring pins pocket and float freely in the holes in the door If not remove the armature and enlarge the holes in the door Insert the shoulder screw armature assembly thru the face of the door...

Page 9: ...achine screws or drill two 11 64 dia holes in the frame for 190 sheet metal screws Secure the mounting plate with the 10 screws and lock washers THE USE OF THESE 10 SCREWS IS IMPORTANT as they provide...

Page 10: ...y used to interconnect the CC 8946 with the cable that connects with the associated Door Control Module in the SIC The diagram below illustrates a typical interconnection using a 16 position terminal...

Page 11: ...11 Figure 5 5 Exploded View of the CC 8946...

Page 12: ...presses the push bar a signal is sent from the CC 8946 to the control module in the SIC The control module then begins a timing sequence typically 15 seconds long The amber lamp begins flashing and t...

Page 13: ...door is open this switch is closed connecting the common return path to the red lamp The Green and Amber lamps are connected to the Magnetic Bond Switch S3 When the magnet is energized and bonded to t...

Page 14: ...erence for all signals 0 Vdc Red Fixed 24 Vdc supply voltage from control module 24 Vdc Orange Red lamp controlled by internal door switch 0 Vdc Yellow Green lamp controlled by internal magnetic bond...

Page 15: ...d door is closed LE12 13 03 Common 24Vdc T1 2 1 3 4 5 6 8 7 R5 BEEP B1 R 4 D2 D3 D4 D6 D5 Test S1 Mag Lock 2 1 T3 Push Bar Switch RED BLK WHT 9 10 T2 WHT Red Lamp Green Lamp Yellow Lamp Buzzer 3 kOhm...

Page 16: ...or replacement of a defective part shall be at the option of the factory when the product is shipped prepaid and insured by the owner This warranty is void in cases of abuse misuse mishandling or repa...

Reviews: