– 21 –
Note: The screw does not need to be loosened
from the clamp to complete the following step.
5. Remove the capillary from the clamp at the
evaporator fan.
Note: During reassembly, you must place the end
of the capillary through the clamp and on the foam
pad.
GEA00682
Capillary
Capillary
Clamp
Clamp
Foam
Pad
Foam
Pad
6. Remove 2 Phillips screws and the temperature
control from the bracket.
GEA00654
Temperature
Control
Temperature
Control
Bracket
Bracket
Wires
Wires
Screws
Screws
7. Disconnect 2 wires from the temperature
control if not already done.
Evaporator Fan (Refrigerator and Freezer)
1. Remove the icemaker (freezer only), upper
light shield, and rear duct (see pages 17-20).
2. Remove 2 screws from the fan motor bracket
and carefully lower the evaporator fan
assembly.
GEA00683
Screws
Screws
3. Disconnect the wire connector from the fan
motor.
GEA00684
Screws
Screws
Fan
Fan
Fan Motor
Fan Motor
Bracket
Fan Motor
Bracket
Wire
Connector
Wire
Connector
Fan Motor
Fan Motor
4. Remove the fan from the motor.
5. Remove 2 screws and the fan motor bracket
from the fan motor.
Summary of Contents for Monogram ZIFS36N RH