background image

10

ZX24NGB

Natural Gas Conversion Kit

Parts supplied:
• Natural gas regulator
• Natural gas orifices
• Adapter 1/2" to 3/8" flare fitting
• Two, 1/2" NPT close nipple

Materials Required:
(not supplied)
• 12 ft. to 15 ft. max. flexible hose with 3/8"

flare end (corrugated stainless steel
preferred).

• Pipe wrench
• Pipe threading compound
• Manual gas shut-off valve
• Appropriate length of gas line to reach the

permanent installation location with a 3/8"
flare end.

• Flat blade screwdriver

Note: 

Optional ZX144HKY quick disconnect hose for natural gas is

available to reach a 144" connection.

Step 1
Install
Fittings &
Regulator

The grill and its individual shut-off valve must
be disconnected from the gas supply during
any pressure testing of the system at test
pressures in excess of 1/2 PSIG.

The grill must be isolated from the gas supply
system by closing its individual shut-off valve
during any pressure testing of the system at
test pressures equal to or less than 1/2 PSIG.

Check with local gas utility or with local codes
for instructions on installing gas supply lines.
Be sure to check on type and size of run and
how deep to bury the line. If the gas line is too
small, the grill will not function properly.
• Install a manual gas shut-off valve in an easily

accessible location.

• Use threading compound on non-flare

fittings only. Do not use threading compound
on the male end of the 1/2 NPT to 3/8 flare
adapter.

• Make connections as shown.
• Remove quick disconnect hose assembly from

manifold pipe.

• Leave flare fitting in the manifold pipe (1/2"

to 3/8" flare).

• Attach installer supplied gas line to end of

flare fitting on the manifold.

• Install regulator to gas line.
• Install 1/2" NPT close nipple to supplier

installed shut-off valve.

• Check to be sure the regulator arrow points

in the direction of gas flow, towards the grill
and away from the gas supply.

The installation of this grill must conform
with local codes or, in the absence of local
codes, with the National fuel gas code, ANSI
Z223 latest edition. Installation in Canada
must be in accordance with the Standard CAN
1-b149-1 and/or .2 (installation code for gas
burning appliances and equipment) and local
codes.

Operating pressure is 4" W.C.
Supply pressure should be 5" to 14" W.C. If
pressure is more than 14" W.C. a step down
regulator is required.

Natural Gas 4.0" Regulator

Adapter 1/2 NPT 
to 3/8" Flare Fitting

1/2 NPT Close Nipple

Installer Supplied
Shut-Off 

Installer 
Supplied 
TUBING 
(3/8" FLARE)

1/2 NPT Close Nipple

Natural Gas Supply

Summary of Contents for ZGG24L

Page 1: ...GE Monogram Installation Instructions 24 Outdoor Cooking Center Model ZGG24L ...

Page 2: ... rusty or damaged LP tank Never substitute gases natural for LP or LP for natural This grill is factory set for liquid propane gas A natural gas conversion kit must be installed before using natural gas When storing the grill indoors disconnect the LP tank Store the tank outdoors in a well ventilated area Do not store additional LP tanks in or near the gas grill Follow the guidelines on the LP tan...

Page 3: ...ck and sides of an enclosure Product Dimensions Clearances Accessories 9 24 3 4 12 Clearance to Combustibles Both Sides 24 Cutout 9 Design Information 24 Outdoor Cooking Center ZX24TKBSS is available to conceal the gap between the cooking center and the enclosure ZX24CVC tough vinyl on the outside felt lined inside with elastic to hold the cover in place Fits grill installed on a cart or when buil...

Page 4: ...ill lid and remove hardware accessory carton Check contents Type 1 Acme 20 Lb LP Tank with Overfill Protection Device not supplied Order ZXLPY Required for Grill Cart Installation 2 Ceramic Briquette Trays 2 Grill Grates LP Regulator Rotisserie Rod and Handle Spit Forks Motor This Cooking Center is extremely heavy 2 people are required for lifting and placing the product onto a cart or into an enc...

Page 5: ...g and handling the rotisserie motor and skewer Allow at least 12 clearance on each side and rear to combustible vertical materials Built In Installations ZX24TKBSS Trim Kit This kit is available for non combustible enclosures The trim will conceal the gap at the rear and both sides of the opening Secure trim to the sides and back with screws provided Place the grill into the enclosure Built In Ins...

Page 6: ...or hose assembly with a standard 510 POL tank valve assembly ELECTRICAL SUPPLY The rotisserie requires 120V 60Hz and connected to an individual properly grounded branch circuit protected by a 15 amp circuit breaker or time delay fuse The power cord on the rotisserie is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possi...

Page 7: ...FF position Turn gas supply on at the LP tank or shut off valve NOTE When lighting the burner for the first time or after a LP tank change allow up to 20 seconds to purge air from the lines Push and turn control knob to LITE position immediately turn the rotary igniter knob next to the burner knob Step 5 Lighting the Grill NOTE The spark will produce a snapping sound This is normal If the burner d...

Page 8: ...e the opening Once adjusted turn the burner off and reverse steps to re install the valve panel cover Low setting Adjustment Minor adjustments may be required due to fluctuations in local gas pressure Adjustments to increase or decrease gas flow may be necessary Turn burner knob to LITE position Turn the control knob to the lowest setting all the way counter clockwise Remove the knob by pulling st...

Page 9: ...n the left side support Screw handle onto the threaded end of the skewer Install Optional Access Doors ZXADYSS and ZXSDBSS For Built In Installations Only ZXADYSS Double Doors The opening should be 24 1 8 wide and 18 1 4 high ZXSDBSS Single Doors The opening should be 22 wide and 20 high Installation 24 Outdoor Cooking Center Place the frame into the opening and secure with screws on all sides Han...

Page 10: ...as line is too small the grill will not function properly Install a manual gas shut off valve in an easily accessible location Use threading compound on non flare fittings only Do not use threading compound on the male end of the 1 2 NPT to 3 8 flare adapter Make connections as shown Remove quick disconnect hose assembly from manifold pipe Leave flare fitting in the manifold pipe 1 2 to 3 8 flare ...

Page 11: ...ive noise or lifting from the burner If any of these conditions exist check air shutter and burner ports for debris or spider webs To Adjust If the flame is yellow indicating insufficient air open the air shutter to allow more air to the burner If the flame is noisy and tends to lift away from the burner there is too much air Turn the air shutter to reduce the opening 1 1 2 3 8 ATTENTION V ERIFICA...

Page 12: ...hould be worn For Monogram local service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice GE Consumer Products General Electric Company Louisville KY 40225 2003 General Electric Company Monogram We bring good things to life ...

Reviews: