31
31-1000600 Rev. 0
Water And Electrical Locations
Electrical and water supply must be located as shown.
For 24” Deep Cutouts
Trim Retro kits are required for a 35.5” (ZKR36R),
36”(ZKR36R), 41.5”(ZKR42N), 47.5”(ZKR48N) or
71.5”(ZKR72R) wide opening.
Heater Unification Kit ZKUN required
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
For a 90° door swing, allow 5 1/8” (13.0 cm) minimum
clearance to a wall.
When installed in a corner, allow 15” (38.1 cm) for a full
115° door swing on 18” and 24” models. Allow 16 9/16”
(42.1 cm) on 30” models. Allow 19” (48.3cm) on 36” models.
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4” O.D. copper tubing or
QuickConnect
™
kit (WX08X10006) between the cold
water line and water connection location, long enough
to extend to the front of the unit (8’ [2.4m]). Installation
of an easily accessible shut-off valve in the water line
is required.
DUAL RETRO-FIT INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
Design Guide - Dual Retro-Fit Installation
Enclosure
Width
Electric
Location
35 1/2" (90.2)
15" (38.1)
36" (91.4)
15" (38.1)
41 1/2" (105.4)
18" (45.7)
47 1/2" (120.7)
20" (50.8)
71.5" (181.6)
32" (81.3)
*83 1/2" min.
*84 1/2" max.
(212.1 – 214.6)
*Trim will overlap
additional 5/8"
75"
(190.5)
)URPÀRRU
to bottom
of electrical
area
24" (61.0)
W
WATER
E
Front View
Enclosure Width
Electric Location
Side View
Finished
Return
6"
(15.2)
6"
(15.2)
3 1/2"
(8.9)
5"
(12.7)
5"
(12.7)
5"
(12.7)
3/4"
(1.91)