47
31-1000600 Rev. 0
Design Guide - Single Integrated Installation
SINGLE INTEGRATED INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 25”.
Additional Specifications
Ŷ
A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall. Electrical must be located on rear wall as
shown.
Ŷ:DWHUOLQHPXVWEHORFDWHGRQWKHEDFNZDOODVVKRZQ
The water line should be 1/4” O.D. copper tubing or
QuickConnect™ kit (WX08X10006) between the cold
water line and water connection location, long enough
to extend to the front of the unit (8’ [2.4 m]). Installation
of an easily accessible shut-off valve in the water line is
required.
Ŷ$PLQLPXPRI´FPILQLVKHGUHWXUQPDWFKLQJ
cabinet exterior is recommended on interior on all sides
and top at front of opening.
Ŷ,QVWDOODWLRQVZLWK´FPRUOHVVEHWZHHQXQLWV
require Heater Kit
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
For a 90° door swing, allow 5 1/8 (13.0 cm) minimum
clearance to a wall.
When installed in a corner, allow 15” (38.1 cm) for a full 115°
door swing on 18” and 24” models. Allow 16 9/16” (42.1 cm)
on 30” models. Allow 19” (48.3cm) on 36” models.
PRODUCT
ENCLOSURE
WIDTH
A
B
C
D
18
17 13/16
4 1/8
3 1/2
7 1/2
2
45.2
10.5
8.9
19.1
5.1
24
23 13/16
4 3/8
5
9 1/2
4
60.5
11.1
12.7
24.1
10.2
30
29 13/16
4 3/8
5
9 1/2
4
75.7
11.1
12.7
24.1
10.2
36
35 13/16
8
9
18
9
91.0
20.3
22.9
45.7
22.9
84" (213.4)
2 1/2" (6.4)
25" (63.5)
A
B
C
D
Enclosure Width
(See Chart)
Finished
Return
ELECTRIC
WATER
6" (15.2)