49-80152 Rev. 8
9
Installation Instructions
1
DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
■ Use a level to draw the cooktop centerline location.
Draw the line to ceiling height.
■ Measure desired distance from the bottom of the hood
to the cooking surface.
NOTE:
If you are installing the hood with duct covers,
be sure to read “Using Duct Cover Accessories” page 4.
Exact installation height may be determined by use of
one or more duct covers.
■ Determine bottom
of hood location
(Dimension A) by
subtracting 12-1/2”
from the desired
installation height.
■ Use a level to draw
a straight horizontal
pencil line indicating
the bottom of the
hood.
■ From the line indicating the bottom of the hood,
measure 20” up and draw another line for the location
of the wood support. See illustration.
FOR VERTICAL (Straight Up) DUCTING
■ Use a level to draw a centerline from the bottom of the
hood to ceiling or soffit.
■ If venting out the ceiling, extend the centerline forward
on the ceiling or soffit.
■ Locate the centerline of a 10-1/2” hole on the ceiling
or soffit by measuring 6” from the wall.
FOR DUCTING THROUGH REAR WALL
■ Measure 9-7/8” above the marked line for the top of
the hood. At the centerline, mark location for a 10-1/2”
diameter hole.
*See recessed
location below.
Top of Hood
Bottom of Hood
22-1/2"
20"
Wood
Support
*House Wiring
Location
Dimension A
Cooking Surface
9-7/8"
House Wiring Location
■ The junction box is fastened to the back of the hood
on the right side.
■ The recessed back side of the hood provides a large
area for the house wiring to exit the wall and be routed
to the rear knockout and junction box.
■ The location for the house wiring depends on the
installation height of the hood and the width of the hood.
■ Remove junction box cover and knockout. Install
strain relief.
Alternate Knockout Locations
If the installation requires, the junction box can be
relocated from the back to the top of the hood. Remove
3 screws, align box to top knockout and secure with
original screws.
■ Remove junction box cover and knockout. Install strain
relief.
14-1/4"
14" for 48" Models
8" for 36" Models
5" for 30" Models
Electrical
Area
6-1/2"
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
Dim. A
Installation
Height