21
Installation Instructions
INSTALLATION – RECIRCULATING
INSTALL FILTERS
•
There are two channels inside the back and front of the
hood. These channels will hold the charcoal filters and
stainless steel grease filters in place.
Install charcoal filters
•
Remove protective film on the charcoal filters.
•
Tip charcoal filters into the
upper (top) channels
at the
rear of the opening. Grasp the filter tab, lift and pull
forward until it rests in the front upper channel.
•
Install all 3 charcoal filters.
Install grease filters
•
Remove protective film from grease filters.
•
Tip the grease filter into the lower channel at the rear of
the opening. Push back, lift and pull the knob forward
until the filter rests on the channel.
•
Install all 3 grease filters.
•
Turn power on. If the filter light on the control panel glows,
adjust the right-side filter in the channel to engage the
switch arm.
10
658Dia25A
Upper charcoal
filter channel
Grasp tab,
lift and pull forward
658Dia59
Lower charcoal
filter channel
Upper charcoal
filter channel
658Dia27A
Lower
filter channel
FINALIZE INSTALLATION
•
Remove protective film covering the control panel
on the front face of the hood and any remaining
packaging materials.
•
Make sure the filters are seated properly when
installed and the filter light is not on.
•
Be sure fan and lights operate correctly. Refer to
the Owner’s Manual for operating instructions
and the Problem Solver.