Masking
tape
Gloves
Utility knife
6
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15- or 20-amp
circuit breaker or time-delay fuse.
• Wiring must be 2-wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible. Route additional length from
ceiling joists to reach the junction box on the
hood.
• Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a
ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING:
The improper connection
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if you are in
doubt whether the appliance is properly grounded.
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Pencil and tape measure
Pliers
Wire cutter/stripper
Metal snips
Spirit level
Aluminized
duct tape
Safety glasses
120V, 60Hz. 15- or 20-Amp,
2-wire with ground, properly
grounded branch circuit
Stepladder
Saber saw or keyhole saw
Phillips screwdriver
Strain relief for
junction box
6
″
round metal
duct, length to suit
installation
Hammer
Flashlight
UL-listed wire nuts
Installation Preparation
Electric drill with 5/32
″
bits,
#2 Phillips and 7/16
″
socket
10 mm wrench
Plumb
Summary of Contents for ZV850
Page 42: ...Notes 42 ...
Page 63: ...63 Notas ...