49-80329 Rev. 5
21
Installation Instructions
INSTALLATION—RECIRCULATING
9
CONNECT CABLES
■ Join the two cable connectors at the front of the hood.
Secure the cables behind the retainer clip.
10
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with a
ground wire, a ground must be provided by the installer.
When house wiring is aluminum, be sure to use U.L.
approved anti-oxidant compound and aluminum-to-
copper connectors.
■ Remove junction box cover and knockout on the
left side.
■ Secure the house wiring to the junction box with a
strain relief.
■ Connect white leads to branch circuit white lead.
■ Connect black leads to branch circuit black lead.
■ Connect green/yellow leads to branch circuit green
lead or bare ground lead.
■ Secure all connections with wire nuts on each
electrical connector.
■ Push wires into junction box and replace cover. Be
sure wires are not pinched.
■ Secure J-Box cover with original screw.
Retainer
clip
To lights
To control
panel
Knockout
J-Box cover
J-Box cover
House wiring
1” = 2.5 cm; 1’ = 0.3 m