4
31-2000730 Rev. 0
Installation Instructions
INSTALLATION CLEARANCES
This hood is designed to be installed onto a wall.
Install this hood 30" minimum to 36" maximum above the
cooking surface.
In this installation, the ductwork running from the top
of the hood will be concealed in the soffit or upper
cabinetry.
In this installation, the ductwork running from the back
of the hood goes directly into the wall.
ADVANCED PLANNING
Ductwork Planning
■ Carefully review the ductwork installation method as
described later in this instruction as well as the hood
insert installation instructions.
Wall Framing for Adequate Support
■ This hood is heavy. Adequate structural support must
be provided. Hood must be secured to vertical studs in
the wall.
■ It is strongly recommended that the hood and hood
insert be on site before final framing and wall finishing.
This will also help to accurately locate the ductwork
and electrical service.
UNBOXING
NOTE:
Clearances may vary due to type of
cooking product and local codes. Check with local
inspectors to be sure standard is applicable.
SOFFIT OR UPPER CABINETS
Top Vent Installation
30" MIN.
36" MAX.
Back Vent Installation
30" MIN.
36" MAX.
Cut Straps
Remove Top
Remove Sleeve
Remove Hood
1” = 2.5 cm; 1’ = 0.3 m