82
ENGLISH
ALARMS
DISPLAY
EXPLANATION
SOLUTION
Indicates the presence of an alarm.
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor
The alarm can be reset only if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing the key 1/
for 3 seconds.
ASPIRATOR
FAULT
Fumes motor fault
Contact after-sales centre
FUMES PROBE
Fumes probe failure.
Contact after-sales centre
HOT FUMES
High flue gas temperature
Check pellet feed (see “Easy setup”). If the problem cannot be solved,
contact an authorised technician.
NO
IGNITION
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped
Check for the presence of pellets in the feed-box.
Adjust the pellet flow (see “Easy setup”).
Check the procedures described in the “Ignition” chapter.
Check the thermostats with bulbs (see chapter on resetting)
NO FLAME
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed pellets.
Check for the presence of pellets in the feed-box.
Adjust the pellet flow (see “Easy setup”).
ALL DEPR
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
TRAPDOOR FAULTY
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly. Check that the burn pot is free and
clean The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre
PRESSURE SENSOR
FAULTY
Differential pressure sensor faulty, disconnected
or broken.
Contact after-sales centre
AUGER CONTROL
Abnormal pellet loading.
Contact after-sales centre
AUGER BLOCK
Abnormal operation of pellet motor.
Contact after-sales centre
TANK EMPTY
The pellet feed-box is empty.
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked.
Check for the presence of pellets in the feed-box.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
MAX CURRENT
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is free and clean
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre
CLOSE
TANK - DOOR
Pellet tank open.
Door open.
Air inlet clogged or dirty.
Make sure that the pellet tank, door and ash drawer close properly.
Check air inlet.