S506
26” Electric Bicycle
©2019 MONSTERPRO
11
Special Functions / Parameter setting
Changing the settings for some functions may cause the bicycle to operate abnormally or in a way that
may appear to be a fault. Take extra care when using any special function to avoid making a setting that
may adversely affect bicycle operation or how you want it to operate.
Changing settings that may affect electrical components of the bicycle or render it unsafe may void
warranty. Some of the parameter is not changeable due to controller model and limit.
Parameter setting
To enter the parameter setting mode, hold the TOP and DOWN buttons at the same time for 3s.
Parameter setting mode will quick if not operation during 10s.
In parameter setting mode, press TOP/DOWN buttons will change parameter value and short press ON
button will save the value to the system.
P01-back light lightness
P02-kmh/MPH (Switch kmh/MPH)
P03-Working voltage (Default value is 36V)
P04-Auto shutdown time (screen automatically if no operation, 0 means never shut down, switch from 0
to 60, Default value is 10 minutes)
P05-Number of Assist levels (0=3 assist levels, 1=5 assist levels, 2=9 assist levels)
P06-Wheel size selection (Wheel Size, default is 26")
P07-Number of magnets for speed sensor, switch from 1 to 100
P08-Speed limit (set the speed limit from 0 to 100Km/h, 100 means no limit)
P09-Non-zero speed start: (0: Zero speed start, 1: Non-zero speed start)
P10-Driving mode selection:
•
0
:
Assist mode (throttle does not work, only pedal assist);
•
1
:
Electrical driving mode(only throttle works, pedal assist does not work) ;
•
2
:
Both pedal assist and electrical driving mode (Not available if in zero speed start and
electrical driving mode)
P11-assist sensitivity setting (switch from 1 to 24)
P12-assist starting power setting (switch from 0 to 5)
P13-Assist magnetic disc types (switch from 5->8->12, different numbers of magnets)
P14-Current limit for the controller (switch from 1 to 20A)
P15-low voltage protection for controller
P16-Reset ODO distance
P17-Reset all parameters
•
Hold press 5 seconds until displays
“
SSSS
”
, all parameters reset to default values(except for the
ODO distance)
P18-Max RPM of the motor (switch from 120 to 1000 RPM)
P19-PAS Magnet calibration for the controller (switch from 0 to 1)
P20-Number of magnets for freewheel speed sensor (switch from 0 to 20)