7. TROUBLESHOOTING
No response
Check the mains power cord is firmly plugged.
Try to turn ON other units the check if they’re powered. If the LCD is lit, the unit needs maintenance.
No output sound
Please check the connections. Check the MUTE front panel keys status. Check the Output Gain settings.
LCD not lit
Please check the power supply cord, otherwise your unit needs maintenance.
Inputs indicator do not lit
Check the input signal (the signal from your audio source).
Distorted sound
Check the signal output from your source. Check the INPUTS levels and your “Gain In” settings.
Then check the OUT Gain settings.
Check the processing parameters, in particular EQ settings.
Check also the output signal path, i.e. if the LOW outputs are wrongly connected to MID amplifiers inputs
LM260
needs immediate maintenance in following cases:
1. If water or other liquids have dripped over or into the cabinet
2. When you feel an unpleasant smell of burnt
3. If the cabinet has severe indentation and deformation
4. When the keys and/or the DIAL are stuck
In above cases and in any other situation where you feel your
LM260
is not properly working, please immediately contact your dealer, your
country tech support, or us writing to:
mail@fiveo.it
.