Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70), including 

fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to 

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) 

or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts 

In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure (or the 

ceiling joist).

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. JY1126R manufactured by Satellite 

Electronic (Zhongshan) Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation.

Note

: Suitable for use in wet locations when installed in a GFCI protected branch circuit.   

  
  

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Summary of Contents for 3JVR58 D Series

Page 1: ... NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3JVR58XXXD Series Fan cETL Model NO 3JVR58XXD 7 36 kg 16 2 lbs Owner s Guide and Installation Manual ...

Page 2: ...building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed...

Page 3: ... box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Install the mounting bracket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the mounting bracket in position and tighten the set screws Inst...

Page 4: ...jury Install ball end of downrod into mounting bracket opening Align engage slot on ball with tab on mounting bracket Warning Failure to align slot on ball with tab may result in serious injury Important If using the angle mount make sure open end of mounting bracket is installed facing the higher point of the ceiling and make sure the ceiling angle is not steeper than 20º Longer downrod may be ne...

Page 5: ...e outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box Caution The installation has to be complete before operate the fan Receiver has to be used on the fan and cannot be bypassed Attach light pan onto the plate on motor Place light pan over the lead wires from fan aligning the keyhole slots on the light pan with the preassembled screws on the...

Page 6: ...from fan to black or blue wire from LED light fixture Attach LED light fixture onto the light pan aligning the keyhole slots on the light fixture with the preassembled screws on the light pan and twist clockwise till lock Reinstall the screw removed in step 17 Tighten all screws securely Attach light shade by locating dimples in light pan with grooves on the light shade and twist clockwise until t...

Page 7: ...e Press the Breeze button the fan will operate at high speed 6th for 30 seconds then automatically change to 5th 4th 3rd 2nd 1st at intervals of 30 seconds and then change it from Low speed 1st to 2nd 3rd 4th 5th 6th repeat the cycle until the breeze mode is canceled Breeze mode can be erased by pressing either the power or speed control buttons Note This remote controller has auto resume function...

Page 8: ...matically after installation it is still using the factory setting Follow the settings for Learn Mode above to reset 2 If the fan or light isn t working reset power turn the power off then turn the power back on and follow the Universal Mode or Learn Mode remote control settings 3 If two or more fans in the same remote signal range are on the same power supply they cannot be operated separately by...

Page 9: ...ounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceiling Keeping measure within 1 8 rotate the fan until the next blade is positio...

Page 10: ...Jun 2022 ...

Reviews: