background image

© 2011 Monte Carlo Fan Company

4/20/2012

5

Loosen 2 screws and remove 1 screw

and save.

27

Attach blade assembly to motor

using the motor screws and washers

provided. Tighten screws securely.

26

Install 3 screws and washers per

blade and tighten securely.  Repeat

for all 5  blades.

25

Place the gasket onto the blade

bracket as shown above.

23

Warning: Only blades that come

with the fan are accepatable for

installation.

Place blade onto blade bracket with

gasket. 

24

Make sure that all exposed wiring is

secured inside wire nuts. Note: Wires

from house may vary in color and

may not include ground wire. After

wiring is conplete, gently push wires

into junction box with wire nuts

pointing upward. Refer to point 3 of

safety tips.

21

House

Fan

Black

White

Green

Black

White

Green(downrod)

Green(Bracket)

Make wire connections to power source using

wire nuts provided.  Make sure that no filiments

are outside of the wirenut. After making the

wire connections, the wires should be spread

apart with the grounded conductor and the

equipment-grounding conductor on one side of

the outlet box and ungrounded conductor on

the other side of the outlet box.

20

For Canadian installation and for USA fan and

light kit combinations over 35 lbs, in both flush

and downrod mode the safety cable must be

installed into the house structure beams using

the 3” lag screws,washers, and lock washers.

provided.  Make sure that when the safety cable

is fully extended the leadwires are longer than

the cable and no stress is placed on the lead-

wires.

19

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Loosen one and remove one preassem-

bled screw from mounting bracket. Save

screw. Lift canopy up, aligning its keyhole

slot with the preassembled screw on

mounting bracket and twist clockwise to

lock in place. Re-install the removed

screw and tighten all screws securely. 

22

Summary of Contents for 5DCR60XX Series

Page 1: ...RESS To register your fixture please visit our website www montecarlofans com 5DCR60XX Series Fan Total fan weight UL Model No AC 560DC 11 kgs 24 2 lbs Warning Only blades that come with the fan are ac cepatable for installation Warning This fan uses dimmable remote controller Do not install light kit with SBCFL Self Ballasted Com pact Fluorescent Lamp on this fan ...

Page 2: ... Box Marked Acceptable for Fan Support of 31 8 kg 70 lbs or less And Use Mounting Screws Provided With The Outlet Box WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce ...

Page 3: ... quali fied electrician if in doubt 2 OUTLET BOX METHOD Secure mounting plate directly to a joist from the buliding structure via the two knock out holes on the outlet box Use only the appropri ate wood screws and washers included with your fan Caution Wood screws must go through into the building joist 5 Outlet box Mounting Plate Wood Screws BUILDING STRUCTURE METHOD Remove the 6 screws attaching...

Page 4: ...r secure downrod Reinstall the downrod ball previously removed Loosen the 2 set screws You should be able to put your downrod into the yoke 10 Remove the shipping stabilizers and discard 15 17 Hang assembled fan from the mounting bracket installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball ...

Page 5: ...re nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 20 For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and do...

Page 6: ... screws previously removed 30 Remove the 3 screws on the switch housing plate and save 29 Install the switch housing plate by aligning the 2 screws with the 2 key slot holes on the plate and twist to lock into place Install the 1 screw removed and tighten the other 2 screws securely 28 ...

Page 7: ...ns can not be controlled separately 2 The fan can remember the running setting before power failure or cut off 3 If the new fan runs after connected to power it may be due to the fan remembering the previous running setting in the factory during the QC process push stop key on transmitter twice to stop Operation Installation 1 Remove the battery cover and the battery from the transmitter you will ...

Page 8: ...ce quickly To turn offpress once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light willmaintain last setting if turned off You can see the percentage on the display screen NOTE If you have more than 1 fan with a remote you will have to change the DIP switch settings located above the battery of the ...

Page 9: ...t a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades ...

Page 10: ......

Reviews: