background image

© 2013 Monte Carlo Fan Company

11/15/2013

2

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.

WARNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnect-

ing means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fas-
ten a prominent warning device, such as a tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.

WARNING

: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: 

For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to
the building structure (or the ceiling joist).

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do

not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING: 

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed

control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

WARNING

Risk of fire, use only compact fluorescent lamps rated 13 watts.

WARNING

This fixture is not dimmable. Use only with on/off switch. Do not use in conjunction fan/light dimmable remote controls or light

dimmers.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Summary of Contents for 5HM52 ND Series

Page 1: ...s card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5HM52XXND Series Fan Total fan weight with light kit UL Model No AC 552 7 8 kgs 17 16 lbs ...

Page 2: ... If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign o...

Page 3: ... appears on the other side Install the Keeper Pin Tighten the 2 Set screws on the Yoke once the downrod is in place Check motor for shipping stabilizers and re move if present Tread leadwires and safety cable first through the canopy disk Canopy and lastly downrod 5 6 4 Canopy disk Downrod Canopy Yoke Cross Pin Keeper Pin Hang assembled fan from the mounting bracket in stalled to ceiling in previo...

Page 4: ...knurled nuts securely The canopy should adjust for any irregularity in the ceiling or Outlet box 13 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 10 Cover Ring House Fan Blue Black White Green Bla...

Page 5: ...using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 23 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from...

Page 6: ...e lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 31 Locate blue and white wire from the fan marked For light kit Connect blue from fan to black from light and white from fan to white from light by pushing connectors together 32 Attach switch cap to fan by lining up 2 slot ear holes and 1 screw hole and twisting cap Then tig...

Page 7: ... 2013 Monte Carlo Fan Company 11 15 2013 7 Align hole in glass and hole in finial cap to allow the fan speed pull chain to pass through Install finial nut and tighten 36 ...

Page 8: ...bove the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest t...

Page 9: ...Jan 2012 new fornmat Jul 2013 Update for CUL regulation Nov 2013 5HM52XXND ...