background image

For Canadian installation in both flush and down-

rod mode the safety cable must be installed into

the house structure beams using the 3” lag screws

provided.  Make sure that when the safety cable is

fully extended the leadwires are longer than the

cable and no stress is placed on the leadwires.

Hang assembled fan from the mounting bracket

installed to ceiling in previous step.  Make sure the

fan is hanging straight.  Rotate fan until the tab on

the Mounting bracket engages the slot on the

Downrod Ball.  This must be done to prevent the fan

body from rotating when the blades are in motion.

7

8

Make wire connections to power source using wire nuts
provided.  Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on
the other side of the outlet box.  

CCaannaaddiiaann m

moouunnttiinngg oonnllyy

Safety Cable

Lag Screw

11

Make sure the studs protruding from the

bottom of the Mounting bracket are

installed with threads all the way through

the bracket.  

9

Pass leadwires  and safety cable

through the canopy.

Remove side covers from canopy expos-

ing  4 holes.  2 closed holes and 2 open

“L” shape holes.

16

FFlluusshh M

Moouunntt IInnssttaallllaattiioonn

15

Lift Canopy allowing the 2 studs to

protrude through the canopy.  

12

Next lift the canopy disk and install

knurled nuts as shown.  Tighten the

knurled nuts securely.  The canopy should

adjust for any irregularity in the ceiling or

Outlet box.

13

Connect black and blue wire from fan to Black or (Hot)

wire from house.  Connect White wire from Fan to

White (Neutral) wire from house.  Connect Ground

leads from mounting bracket and downrod to Ground

lead from house.  

Refer to Safety Tips section of

manual.

10

Canopy disk

House

Fan

Blue 

Black

White

Green

Black

White

Ground

Lag Screw

Washer

Lock Washer

Safety Cable

Go to Step 26

14

Install rubber pad between fan

body and canopy.

18

Remove every other screw as circled

and save for later use.

17

Summary of Contents for 5OR52XXD Series

Page 1: ...QUALITY CEILING FANS Ceiling Fan Installation Instructions For 5OR52XXD Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light kit OWNER S MANUAL ...

Page 2: ...as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked ...

Page 3: ...di ia an n m mo ou un nt ti in ng g o on nl ly y Safety Cable Lag Screw 11 Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket 9 Pass leadwires and safety cable through the canopy Remove side covers from canopy expos ing 4 holes 2 closed holes and 2 open L shape holes 16 F Fl lu us sh h M Mo ou un nt t I In ns st ta al l...

Page 4: ...he hands free hook into a closed hole on the edge of the Canopy Note For Canadian mounting refer to Step 8 21 Hands free hook Take 4 screws from hardware pack and insert 2 one on each side of bracket to match the L slot screw holes in canopy Keep 2 screws for later use 22 Replace the 3 screws removed and tighten securely Check motor for shipping stabilizers and remove if present 20 Place canopy ov...

Page 5: ...ack from light and white from fan to white from light by pushing connectors together 33 Install finial cap and finial nut to glass and tighten finial nut 37 Attach switch cap to fan by lining up 2 slot ear holes and 1 screw hole and twisting cap Then tighten the 3 screws 34 Install rubber washer and hex nut to glass tighten nut 36 Remove finial nut finial cap hex nut and washer from fitter 35 ...

Page 6: ...e unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supp...

Reviews: