REMOTE CONTROL SETTING and OPERATION

Universal Mode and Learning Mode

There are “Universal Mode” and “Learning Mode” with the remote controller. 
If choosing “

Universal Mode

”, simply place dip (code) switch at UPPER 

position. Your fan with the remote controller is ready to use. 

Note

: If using universal mode, your fan can be controlled with other remote 

transmitters with the same setting.
To control the fan with specific remote transmitter, choose “

Learning Mode

” 

by placing the dip (code) switch at LOWER position and then make learn 

function setting as below. 

Learn function setting

, Restore power source to your fan, press and hold 

the “

LEARN

” button for at least 3 seconds. You must press the “

LEARN

” 

button within 60 seconds of restoring power to the fan.

Note

: If the power is on already, you must turn the power off for 10 seconds 

at least, and then turn the power back for remote control learn function 

setting. 

Note

: If the fan is installed with light, light will twinkle 2 times. The remote 

control setting process is complete and your fan is ready for use. For fans 

without light, check operation using remote transmitter. 

Note

: If you want to control the fan with another transmitter, make the same 

setting. A fan can be controlled by 2 transmitters maximum.

Transmitter Operation  

Remove the battery cover from the remote control transmitter and install 

battery, battery provided. Replace the cover.

Note

: Use 2 1.5V/AAA 

 

battery. 

Note

: If not using for long period of time, remove battery to prevent damage 

to remote transmitter, and store the remote transmitter away from excess 

heat or humidity.

ON

DIM

LE

AR

N

L.CODE

COMMON

CODE

L.CODE

COMMON

CODE

ON

DIM

Universal Mold 

Learning Mold

Dimming / Non Dimming Setting

The “DIM” selection is the light dimmable selection and the light will cycle 

from bright to dim to bright until button is released. The “ON” selection is the 

light ON/OFF only (non dimming function). Light will maintain last setting if 

turned off.

Note

: The remote controller is set with dimming function at factory,

 

Note

: If the remote receiver has been wired with fan, turn power off by wall 

switch before switch “DIM” and “ON/OFF” selection.  

Dimming/

Non dimming

LEARN

Learn

The receiver provides the following protective functions

Lock protection- The DC motor has a build-in safety feature against blade or motor obstruction during operation. If 

something obstructs the fan blades or motor, the motor will keep trying to run for 5 times and then stop operation 

after about 60 seconds of interruption. Please remove obstacles and reset. To reset it by turn the fan off by remote 

transmitter and then turn the fan on, Or you may turn power off for 15 seconds then turn power back, and then turn 

the fan on,   

Over load protection (current limit)- The device will limits the maximum current output from the receiver/drive when the 

fan or light load was increased abnormally. 

Summary of Contents for 8EER60 Series

Page 1: ... PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 8EER60XXD Series Fan ETL Model NO 8EER60 XXXXX 10 85 kgs 23 87 lbs 3 0 6 4 9 6 4 ...

Page 2: ... the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be installed with an isolating wall control switch WARNING To reduce the risk of fire ...

Page 3: ...tall the 2 outlet box screws securely Hang motor assembly onto the buckle on mounting plate for hands free wiring and safety cable installation Clasp the cable with hook into the buckle on mounting plate as shown in inset For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams...

Page 4: ...screws removed in step 7 Tighten all screws securely Remove set screws from mounting plate Keep screws Lift fan housing up aligning the holes on housing with the holes on mounting plate Reinstall the set screws remove in step 10 Remove the gasket Align the holes of blade bracket blade and the top plate of blade bracket Install blade bracket with blade and top plate by 3 blade screws provided Tight...

Page 5: ...aligning the keyhole slots on the light pan with the preassembled screws on the plate Twist clockwise till lock Reinstall the screw removed in step 14 Tighten all screws securely Remove 3 set screws from side of light pan Keep screws Connect white wire from fan to white wire from LED light kit and then connect blue wire from fan to blue wire from LED light kit Note If you don t want to install the...

Page 6: ...he holes on LED light kit with the holes on light pan Reinstall the set screws removed in step 17 Tighten screws securely Align the threaded rod in blanking plate with the screw hole in light pan and Install it by turning clockwise till tight Install Blanking Plate Blanking plate Threaded rod ...

Page 7: ...Nov 2014 ...

Page 8: ...emote control transmitter and install battery battery provided Replace the cover Note Use 2 1 5V AAA battery Note If not using for long period of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity ON DIM LEARN L CODE COMMON CODE L CODE COMMON CODE ON DIM Universal Mold Learning Mold Dimming Non Dimming Setting The DIM sele...

Page 9: ...eleased Note This remote controller has auto resume function the fan and light will maintain the last setting if power is turned off Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory 2 If fan or light isn t working reset power turn the power off for at least 10 seconds and then turn th...

Page 10: ...DN LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KR...

Reviews: