Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 

70-1999), including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor 

on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be 

turned upward and pushed carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet 

from the floor to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do 

not insert foreign object between rotating blades.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove 

Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the 

building structure (or the ceiling joist).
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To Reduce The Risk Of Electric Shock, This Fan Must Be Installed With a general use, isolating Wall Control/Switch.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. DC8 manufactured by 

Carewell Electric Technology (Zhongshan) Co.,Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable 

speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating 

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is 

required, the product should be returned to an authorized service facility for examination or repair.   
All set screws must be checked, and re-tightened where necessary, before installation.

Note

: Suitable for use in damp locations.  

  
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Summary of Contents for Prairie 14PRR52 D Series

Page 1: ...ATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 14PRR52XXD Series Fan ETL Model NO 14PRR52 X 10 38 kgs 22 84 lbs ...

Page 2: ... Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To Reduce The Risk Of Electric Shock This Fan Must Be Installed With a general use isolating Wall Control Switch WARNING To redu...

Page 3: ...d by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Remove preassembled keeper pin and cross pin from downrod Place downrod over canopy canopy bottom cap and yoke cover Partially lo...

Page 4: ...ed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above Red from fan to Red from remote marked Motor 1 Purple from fan to Purple from remote marked Motor 2 Gray from fan to Gray from remote marked Motor 3 Blue from fan to Blue from remote marked FOR LIGH...

Page 5: ...sembled screw from the plate on motor Save screw for later use Place light pan over the light lead wires and attach it onto the plate on motor aligning the keyhole slots on the light pan with the preassembled screws on the plate Twist clockwise till lock Reinstall the screw removed in step 15 Tighten all screws securely Lift canopy up aligning its keyhole slot with the preassembled screw on mounti...

Page 6: ...n connect blue or black wire from fan to blue or black wire from LED module Note If you don t want to install the fan with LED light go to step 20 for blanking plate installation Attach lexan shade by locating dimples in light pan with grooves on the Lexan shade and twist clockwise until tight Attach blanking plate by locating dimples in light pan with grooves on the blanking plate and twist clock...

Page 7: ...ote control transmitter and install battery battery provided Replace the cover Note Use 2 1 5V AAA battery Note If not using for long period of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity ON DIM LEARN L CODE COMMON CODE L CODE COMMON CODE ON DIM Universal Mold Learning Mold Dimming Non Dimming Setting The DIM select...

Page 8: ...eased Note This remote controller has auto resume function the fan and light will maintain the last setting if power is turned off Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory 2 If fan or light isn t working reset power turn the power off for at least 10 seconds and then turn the ...

Page 9: ... LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KROG...

Page 10: ...May 2018 ...

Reviews: