FIRE EXTINGUISHING SYSTEM
Your Monterey boat is equipped with a Halon
Automatic Fire Extinguishing System to provide
protection in the event of an engine compartment fire.
The system is automatically actuated when
temperatures reach or exceed a preset limit.
When actuation occurs, a loud popping sound may be
heard followed by “rushing” air sound. When a
discharge occurs, immediately shut down all electrical
and mechanical systems, and powered ventilation if
not already done automatically by means of the
pressure switch (optional).
Do not open the engine hatch at this time! This feeds
oxygen to the fire and flashback can occur. Allow the
Halon extinguishing agent to “soak” the compartment for at least fifteen (15)
minutes, and wait for hot metals and fuels to cool before inspecting for cause
or damage.
Halon and fire by-product fumes are toxic; do not breath halon
or fire fumes. Accidental discharge can be dangerous and may
cause serious injury. Do not attempt to service the system
unless qualified to do so.
Halon fire extinguisher cylinders must be accurately weighed
periodically according to manufacturer's specifications to
ensure that they are adequately charged.
TROUBLESHOOTING
The following charts will assist you in finding and correcting minor
mechanical and electrical problems with your boat. Contact your nearest
authorized Monterey dealer for problems and procedures requiring the skill of
a trained service technician.
Engine and Power Train
Note
For further troubleshooting information other than given here,
refer to the individual component owner’s manual.
!
CAUTION
M-3
SYSTEM
DISCHARGED
SYSTEM
CHARGED
AUTOMATIC
HALON FIRE
EXTINGUISHING
SYSTEM
KC-0084
!
WARNING
!
Monterey Cruiser 7/18/08 2:56 PM Page M-3