How to Use

Control Panel Functions

1.  After the unit is properly installed and plugged in, press the power button to turn ON.
2.  Press the mode button to select desired setting:

•  Energy Saver:

 The fan will automatically turn off when the compressor stops. 

When the compressor starts again, the fan will turn on.

•  Dry: 

Unit acts as a dehumidifier to pull moisture out of the air.

•  Fan:

 The fan runs, but the condenser does not.

•  Cool:

 When the temperature of the unit is set colder than the air temperature 

of the room, both the compressor and fan will run. But when the room temp 

becomes colder than what is set on the AC, only the fan will run.

3.  If fan mode is selected, press the speed button to choose low, medium or high 

fan speed.

4.  If cool mode is selected, use the time/temp buttons to select desired temperature. 

The range of settings is 64

90

˚

 F. 

5.  Use the air direction control levers to aim the stream of cool air up/down and left/right.

How to Use 

(cont’d)

Remote Control

1

2

3

4

5

6

7

8

9

10

11

12

Remote Control Functions

1.

Signal transmission - Point the remote control at the air conditioner. When 

the signal is received, a beep will sound.

2.

Cool button - Turn on cooling mode. Set the temperature using the +/- buttons.

3.

Dry button -Turn on dehumidifying functionality.

4.

Fan button - Use to vent the inside air through the unit to the outside.

5.

Energy Saver button - Use to start or stop Energy Saver mode, which is only 

functional when cool mode is ON.

6.

ON/OFF button - Press to start or stop operations on the unit.

7.

Timer button - Use this button to set the number of hours (up to 24) the unit 

should run continuously until automatically shutting down. To set the timer, 

press the timer button, then use the + and - buttons to set the number of hours. 

Pressing the timer button when the timer is in use will turn the timer off.

8.

Filter Reset button - When the check filter LED is illuminated, clean the 

filter and then press this button to turn off the LED.

9.-11. The Low, Medium and High Fan buttons - These buttons will set the fan speed. 

The fan will circulate the air in the room, but the condenser will not run.

12.

Increase (+) and Decrease (-) buttons - Use in conjunction with the timer 

button for increasing/decreasing the time or with the cool mode for setting 

the temperature.

Things to keep in mind regarding the remote control:
•  If the air conditioner does not beep, letting you know that the signal has been 

received from the remote, check the batteries.

•  Do NOT place the remote on or near heat-emitting objects, such as a radiator or 

electric blanket.

•  Do NOT put the remote where the sun can shine on it.
•  Do NOT expose the remote to water or other liquids.
•  Do NOT put heavy objects on top of the remote.
•  Avoid accidentally dropping the remote.
Battery Replacement
1.  Turn the remote over and slide the battery cover in the direction of the arrow.
2.  Replace batteries.
3.  Slide cover back into place, making sure it is securely closed.

Summary of Contents for AW121005E

Page 1: ...57 115V 60Hz 3517W Wards com 1 888 557 3848 Montgomery Ward Customer Service 1112 7th Avenue Monroe WI 53566 8 00 a m to Midnight CT Monday through Friday Wards com 1 888 557 3848 Window AC 12000BTU Energy Saving Mode MODEL AW121005E ...

Page 2: ...nsion cord with this appliance 12 Do NOT operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner Call our toll free customer service number for information regarding replacement or returning the product 13 Do NOT remove front grill when machine is in use 14 The back of the unit must be lower than the front of the unit to allow for ade...

Page 3: ...ntrol Lever Air Inlet 10 Air Inlets Parts Features cont d 1 2 3 4 5 6 7 8 9 10 Control Panel 1 Digital Display Room temp fan mode Unit temp cool dry mode Remaining run time on timer 6 Check Filter When the LED is illuminated filter cleaning is necessary 2 Energy Saver Feature is in use when the LED is illuminated 7 Filter Reset Button After cleaning the filter press to turn off check filter LED 3 ...

Page 4: ...control panel frame Installation Your 12000BTU air conditioner is designed to be installed into a standard double hung window with a 31 43 opening width and 19 vertical height Item Name of Part Qty Item Name of Part Qty 1 Side Curtain 2 8 Flat Head Bolt Lock Nut 2 2 Short Screws 10 9 Window Support Bracket 2 3 Wood Screws 13 10 Upper Guide 1 4 Sash Lock 1 11 Window Sash Seal 2 5 Curtain Lock 2 12 ...

Page 5: ...ld be facing out towards you Flange Flange 10 Cut the adhesive backed foam seal Item 11 to the width of the window Remove backing from foam and attach strip to the underside of the window 11 Cut the adhesive backed foam pads Item 8 to the height of the opening and adhere to the insides of the window frame 12 With the window open find and mark the center of the inner sill 13 Place the cabinet in th...

Page 6: ...binet 20 Trim the non adhesive backed window sash seal Item 11 to the width of the window and insert in between the upper and lower sashes This will help to keep out drafts and bugs 21 Attach the sash lock Item 4 to the top of the lower sash and the window frame using 3 wood screws Item 3 22 Place the chassis back into the cabinet making sure that it is firmly seated towards the back of the cabine...

Page 7: ...em Remove screws from Sash Lock total 6 screws Curtain Locks total 2 screws Flanges total 2 screws Upper guide total 2 screws 1 Close curtains on side of the unit 2 Remove the front grill and the air filter 3 Remove and set aside the 4 screws that holds in the louvres and control panel frame 4 Carefully pry the frame away from the cabinet and set aside 5 Remove the ground screw on the lower left c...

Page 8: ...nergy Saver button Use to start or stop Energy Saver mode which is only functional when cool mode is ON 6 ON OFF button Press to start or stop operations on the unit 7 Timer button Use this button to set the number of hours up to 24 the unit should run continuously until automatically shutting down To set the timer press the timer button then use the and buttons to set the number of hours Pressing...

Page 9: ...he interior of the unit 2 Clean the filter 3 Remove the batteries from the remote control Troubleshooting Before calling for service try these troubleshooting tips Problem Possible Cause Remedy AC is cooling but room is still warm 1 Air filter may be dirty 2 Temperature on unit is too warm 3 Air flow is restricted 1 Clean filter 2 Lower temperature 3 Remove any obstacles drapes furniture etc from ...

Page 10: ...our order number and reason for return We recommend keeping the receipt for 4 weeks Returns Montgomery Ward Inc warrants this product to be free from defects in material and workmanship for one year from provable date of purchase Within this warranty period Montgomery Ward will repair or replace at its option defective parts of this product at no charge provided the product is returned freight pre...

Reviews: