Page 4
XG0514-150204
I-Series Indoor Gas Fireplace
Installation
Introduction
Congratulations on your purchase of a
Montigo Fireplace
.
With over 30 years of experience, Montigo is committed to providing
you with a gas fireplace that is not only a beautiful addition to your
space, but that is also designed and manufactured to the highest
safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions
laid out in this Installation, Operation and Maintenance Manual
and retain it for your future reference. Pay special attention to all
cautions, warnings, and notices throughout this manual intended
to ensure your safety.
This manual covers installation, operation and maintenance. Lighting,
operation and care of this fireplace can be easily performed by the
homeowner. All installation and service work should be performed
by a qualified or licensed installer, plumber or gas fitter as certified
by the state, province, region or governing body where the fireplace
is being installed.
This installation, operation and maintenance manual is applicable
to the models described below. Refer to your rating plate to verify
included options.
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
► Modification of the fireplace and/or components including
Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved
by Montigo in combination with this Montigo fireplace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements
for factory-built gas fireplaces. Installation & repairs should be done
by a qualified contractor.
This appliance is equipped for altitudes from 0 - 4500 feet [0
-1370 m]. For higher altitudes contact your Montigo dealer.
34FIDN-L-F
34FIDL-L-F
NG
LP
Input Rating
31,000 BTU
30,000 BTU
Gas Supply Pressure
7" WC
11" WC
Manifold Pressure
High
3.5"
10"
Low
2.2"
6.4"
Orifice Size (DMS)
35
52
Pilot Orifice Size (No.)
62
35
Air Shutter Min Settings
Fully Closed
3/16" Open
Electrical Requirement
115 VAC, 60Hz
115 VAC, 60Hz
Vent Size
4" Exhaust / 3" Intake 4" Exhaust / 3" Intake Aluminum / Stainless Flex
Minimum Vent Length
10'
10'
Maximum Vent Length
36'
36'
Efficiency AFUE Method
70.01%
71.06%
Efficiency P.4 Method
77.40%
78.50%
Clearances
Mantel
17"
17"
Hearth
0"
0"
Side Wall
8"
8"
Control Type
SIT Proflame 2
SIT Proflame 2
Light Bulb Specification
20W, G6.35, Qty 5
20W, G6.35, Qty 5
Fuse Specification
3.15Amps
3.15Amps
Fan Amperage
1.6Amps
1.6Amps
Certification(s)
Ansi Z21.88-2014 / CSA 2.33-2014 VENTED GAS FIREPLACE HEATERS
Certification(s)
CGA 2.17-M91 [R2009] GAS FIRED APPLIANCES FOR HIGH ALTITUDES
CSA P.4.1-09 Fireplace Efficiency
CSA P.4.1-09 [R2014] Fireplace Efficiency
Introduction