Page 41
XG0514-150204
I-Series Indoor Gas Fireplace
Operation
When you turn on the fireplace it starts on high. The proflame 2
has six (6) flame levels. Each time you press the Down Arrow
Key once the flame height will reduce by one step.
You can continue this until the main burner flame turns off. You
can still operate the accent lights and fans in this mode.
If the main burner flame is off and you press the up arrow key
once, the flame will automatically go to high, see
Figures 14
Sec.5 and 15 Sec.5
.
Figure 14 Sec.5
Flame Off and Flame Level 1.
Figure 15 Sec.5
Flame Level 5 and Flame Level Maximum.
Figure 16 Sec.5
Setting Room Thermostat
The Remote Control can operate as a room thermostat. The
thermostat can be set to a desired temperature to control the
comfort level in a room. To activate the function, press the
Thermostat Key, see
Figure 8 Sec.5
. The LCD display on the
remote control will change to show that the room thermostat
is "On" and the set temperature is now displayed, see
Figure
16 Sec.5
To adjust the set temperature press the Up or Down
Arrow Keys until the desired set temperature is displayed on
the LCD screen of the Transmitter.
The Smart Thermostat function adjusts the flame height in
accordance to the difference between the set point temperature
and the actual room temperatures. As the room temperature
gets closer to the set point the Smart Function will modulate the
flame down. To activate the function, press the Thermostat Key,
see
Figure 8 Sec.5
, until the word "SMART" appears to the
right of the temperature bulb graphic, see
Figure 17 Sec.5
.
NOTE:
When smart Thermostat is activated, manual flame
height adjustment is disabled.
Figure 17 Sec.5
Smart flame function
Remote-Flame Control
Room Thermostat (Remote Control Operation)
Smart Thermostat (Remote Control Operation)