Page 8
XG0514-150204
I-Series Indoor Gas Fireplace
Installation
10"
254
Max
17"
432
Min
8 12 "
216
Min.
Mantel
Side Wall
Hearth Protection
Not Required
Faceplate
17"
432
Minimum
10"
254
Max
Allowable
Mantel
Area
25"
27"
29"
31"
33"
35"
37"
39"
10"14"18"24"26"30"34"38"
21"
19"
17"
23"
Figure 3 Sec.2
34DFIDV-LIN mantel clearances
10"
254
Max
17"
432
Min
8 12 "
216
Min.
Mantel
Side Wall
Hearth Protection
Not Required
Faceplate
17"
432
Minimum
10"
254
Max
Allowable
Mantel
Area
25"
27"
29"
31"
33"
35"
37"
39"
10"14"18"24"26"30"34"38"
21"
19"
17"
23"
WARNING
Do not place any materials or objects in front of
door relief. Doing so could result in failure of door
relief system or heat dissipation.
Non Combustible Board Install
Mantle
Side Wall
Gas Insert
Wall Face
Non combustible facing
materials must be used above
the unit, up to the minimum
required mantel height clearance
and for the entire width of the
fireplace opening. This includes
all types of possible installations.
Figure 4 Sec.2
Non Combustible Board Install