Inverter displays and power indicator light up
Power up the Montigo control panel
Yes
No
• Blown fuse
• Incorrect supply voltage
Turn wall switch on
Yes
•
Combustion air relay on
• Power vent starts up
No
• Restricted air intake
• Power vent not connected
Flue gas relay on
Yes
No
• Increase power vent speed
•
Reverse power vent direction
Flue gas relay on
No
Contact Montigo Tech Support
Yes
1 minute system purge
Smart valve relay on
Hot surface igniter glows
No
Yes
• Pressure switch trip
•
Failed purge timer
Yes
Pilot flame lights
No
• Control cable not connected
• Pilot assembly failure
•
Smart valve failure
No
• Air in gas line
• Gas not turned on
Yes
•
Igniter off
•
Smart valve opens
• Main burner lights
No
•
Pilot not touching flame rod
•
Poor ground connection
Turn wall switch off
•
Fireplace burner off
• Power vent purges for 3 minutes
Power vent off
C-VIEW Sequence of Operation
Section 13: Troubleshooting
Page 15
XG0702
Custom C-View Fireplace
Maintenance