background image

Burner Tray Gasket

17

 

This kit should be installed by a qualified person.

 

Check local codes and read all instructions prior to installation.

CAUTION:

 

Ensure that power is off at 

the electrical breaker or fuse 

before beginning installation.

  Ensure the Gas is off at the 

shut-off before beginning 

installation. 

Installing the HFK-Series Cross-Flow Blower 

for use with: H-Series DF/

DL & L-Series DF Gas 

Fireplaces

H34-DF/DL;  L38-DF
H38-DF/DL;  L42-DF
H42-DF/DL;  L52-DF

General Information

This blower kit is for installation on the  foll owing models:
 

 Casa H34DL / H34DF

 

 Villa H38DL / H38DF

 

 Estado H42DL / H42DF

 

 L38-DF, L38-DF-I, L38-DF-A, L38-DF-F

 

 L48-DF, L42-DF-I, L42-DF-A, L42-DF-F

 

 L52-DF, L52-DF-I, L52-DF-A, L52-DF-F

KIT # 

Contents

HFK34 

2 x blowers, 1x fan cord assembly, 4 x mounting screws

HFK34H  2 x blowers, 1x fan cord assemby, 4 x mounting screws, 

                     1x heat sensor switch

HFK42 

2 x blowers, 1x fan cord assembly, 4 x mounting screws

HFK42H  2 x blowers, 1x fan cord assemby, 4 x mounting screws, 

                     1x heat sensor switch

Before You Begin

Ensure that the power supply has been turned off at the breaker or fuse 

before beginning the installation. 
Shut off the gas supply at the shut-off valve, and ensure that the main 

burner and pilot light have been turned off and the fireplace has been 

cooled off for at least two hours be fore installation.

Installation

1a.  Models H34DL, H38DL, and H42DL: Remove  the lower louvres to 

gain access to the control compartment. Go to Step 2.

1b.  Models H-Series and L-Series: Remove  the glass door to gain 

access to the control compartment through the firebox.

2  Remove the accessories inside the firebox; logset, glass pebbles, 

or decorative river rocks, etc

3.  Carefully remove  the decorative horizontal insulation panels.

Figure 2. 

Shut off and disconnect the gas supply.

 

Note: 

Follow the shut-down procedures for the valve installed with 

your fireplace. 

May not be exactly as shown.

(H34DF, H38DF, and H42DF Models Only)

Gas Valve

Pan Base

Gas Inlet

Valve Bracket

 

NOTE: DO NOT CONTINUE UNTIL THIS STEP IS COMPLETED.

®

C

US

Figure 3.

 Removing the burner tray.  (H34DF, H38DF, and H42DF 

Models Only)

5.  Remove the burner tray as shown in figure 3 for the H-DL Series 

gas fireplace, and figure 3a for the L-Series DF fireplace.

4.  Shut off the gas to your fireplace and shut off the control valve. See 

the instruction on the placard supplied with your fireplace. 

Reviews: