Burner Tray Gasket
17
This kit should be installed by a qualified person.
Check local codes and read all instructions prior to installation.
CAUTION:
Ensure that power is off at
the electrical breaker or fuse
before beginning installation.
Ensure the Gas is off at the
shut-off before beginning
installation.
Installing the HFK-Series Cross-Flow Blower
for use with: H-Series DF/
DL & L-Series DF Gas
Fireplaces
H34-DF/DL; L38-DF
H38-DF/DL; L42-DF
H42-DF/DL; L52-DF
General Information
This blower kit is for installation on the foll owing models:
Casa H34DL / H34DF
Villa H38DL / H38DF
Estado H42DL / H42DF
L38-DF, L38-DF-I, L38-DF-A, L38-DF-F
L48-DF, L42-DF-I, L42-DF-A, L42-DF-F
L52-DF, L52-DF-I, L52-DF-A, L52-DF-F
KIT #
Contents
HFK34
2 x blowers, 1x fan cord assembly, 4 x mounting screws
HFK34H 2 x blowers, 1x fan cord assemby, 4 x mounting screws,
1x heat sensor switch
HFK42
2 x blowers, 1x fan cord assembly, 4 x mounting screws
HFK42H 2 x blowers, 1x fan cord assemby, 4 x mounting screws,
1x heat sensor switch
Before You Begin
Ensure that the power supply has been turned off at the breaker or fuse
before beginning the installation.
Shut off the gas supply at the shut-off valve, and ensure that the main
burner and pilot light have been turned off and the fireplace has been
cooled off for at least two hours be fore installation.
Installation
1a. Models H34DL, H38DL, and H42DL: Remove the lower louvres to
gain access to the control compartment. Go to Step 2.
1b. Models H-Series and L-Series: Remove the glass door to gain
access to the control compartment through the firebox.
2 Remove the accessories inside the firebox; logset, glass pebbles,
or decorative river rocks, etc
3. Carefully remove the decorative horizontal insulation panels.
Figure 2.
Shut off and disconnect the gas supply.
Note:
Follow the shut-down procedures for the valve installed with
your fireplace.
May not be exactly as shown.
(H34DF, H38DF, and H42DF Models Only)
Gas Valve
Pan Base
Gas Inlet
Valve Bracket
NOTE: DO NOT CONTINUE UNTIL THIS STEP IS COMPLETED.
®
C
US
Figure 3.
Removing the burner tray. (H34DF, H38DF, and H42DF
Models Only)
5. Remove the burner tray as shown in figure 3 for the H-DL Series
gas fireplace, and figure 3a for the L-Series DF fireplace.
4. Shut off the gas to your fireplace and shut off the control valve. See
the instruction on the placard supplied with your fireplace.