background image

18

Burner Tray Gasket

XG0625 - 081008

Figure 6. 

Installing the heat sensor.

Heat sensor

Blower power cord

6.  Install the first blower on the left side. Attach the connections on 

the fan cord with the connections on the blower. On models H34-

DL, H38-DL, and L42-DL, slide the blowers carefully into place to 

the right of the valve. Take care not to damage any pilot tubing or 

gas controls. On models L38-DF and L-42-DF, slide the blower into 

place carefully through the opening in the base of the firebox.

7.  Install the second blower on the right side. Attach the  remaining 

connections on the fan cord with the connections on the blower. 

On models H34-DL, H38-DL, slide the blowers carefully into place 

to the right of the valve. Take care not to damage any pilot tubing 

or gas controls. On models L38-DF, L42-DF and L-52-DF, slide the 

blower into place carefully through the opening in the base of the 

firebox.

Figure 4. 

Positioning the blower on the left side.

Figure 5. 

Positioning the blower on the right side.

Installing the HFK34/ HFK34H Cross-Flow Blower 

        Plug the blower's power cord into the receptacle on the PPO 

box.

10.  Install the heat sensor switch contained in the HFK34H blower 

kit: 

On models H34DF, H38DF, and H42DF, reinstall the burner 

tray as outlined in step 1b and shown in figure 2. 

Install the heat sensor switch by sliding it into place under-

neath the burner tray to the right of the gas valve, as shown 

below.

11.  On models H34DF, H38DF, and H42DF, CAREFULLY reinstall 

the log base and logset and ensure that they are properly po-

sitioned as outlined in the fireplace's operation and installation 

manual. Once the logset in properly positioned, replace the 

glass door. On -L-Series models replace the ceramic panel(s), 

decorative beads, and/or decorative rocks.

12.  Replace the door as shown in your instruction guide.
13.  Turn on the power supply and reconnect the gas supply.

8.  On each blower, position the inside of the front top edge with 

the mounting brackets on each side of the control compart-

ment, as shown in figures 4 and 5. Fasten both blowers in 

place with self tapping screws.

9.  If the PPO box has not been factory installed, ensure that the 

household electrical supply is shut off at the breaker or fuse, 

and connect the two wire leads from the box to the household 

electrical supply. Insert the PPO box into the square hole in 

the right-hand side of the control compartment and screw into 

place.

Figure 3a.

 Removing the burner tray. (L38DF, L42DF. L52DF Only)

Sensor

Mounting Plate