H36PVN Power Vent Indoor Gas Fireplace
Page 12
XG0649 - 031511
Installation
Figure 5g. (Installation of Power Vent Module)
Install Power Vent Module
with Power / Communication
Harness
Vertical Roof Top
Power Vent
Vertical Roof Top
Power Vent Rough-
in Kit
Step 5.
Install the Power Vent, Roof-top Stainless steel cover over the
Installed Rough-in Kit . (You can see the Electrical harness connector
in the top right corner) .
Figure 5e. Figure 5f.
Step 6.
Install the Power Vent Module Power / communication harness .
Hold the Power Vent in close proximity of the assembled Chase,
(with stainless steel cover attached) and plug in the Power Vent
communication / Power Cord . (Note the direction and orientation of
the plug socket) . (See Figure 5e & Figure 5f)
Electrical Harness
from Power Vent
Step 7.
Install the Power Vent Module . Place the Power Vent Module
over the stainless steel cover flange and vent pipe, aligning the
Power Vent into final position . Ensure the Harness is placed down
in the Rough-in box when placing the Power Vent Module into place .
The Power Vent Module will sit flush with the stainless steel cover
if installed correctly .
Figure 5h. (Installed Power Vent Module)
Step 8.
Install (3) three stainless steel fasteners around Power Vent
Module @120 degrees (penetrating through the inner stainless steel
vent cover)
Stainless Steel
Fasteners
CAUTION!
Vent terminations can be very hot. The termination is to be installed higher than 7 feet above a public walkway.
Do not obstruct, or attempt to conceal, the vent termination. These actions will affect the operation of the fireplace, and may be hazardous.
In heavy snow areas, take extra care to prevent snow buildup from obstructing the vent termination.
■ Vent terminations can be very hot. The
termination is to be installed higher than 7 feet
above a public walkway.
■ Do not obstruct, or attempt to conceal, the vent
termination. These actions will affect the operation
of the fireplace, and may be hazardous.
■ In heavy snow areas, take extra care to
prevent snow buildup from obstructing the vent
termination.
CAUTION
XW2026